The occurrence of the Coanda effect in pulsatile flow through static models of the human vocal folds.
نویسندگان
چکیده
Pulsatile flow through a one-sided diffuser and static divergent vocal-fold models is investigated to ascertain the relevance of viscous-driven flow asymmetries in the larynx. The models were 7.5 times real size, and the flow was scaled to match Reynolds and Strouhal numbers, as well as the translaryngeal pressure drop. The Reynolds number varied from 0-2000, for flow oscillation frequencies corresponding to 100 and 150 Hz life-size. Of particular interest was the development of glottal flow skewing by attachment to the bounding walls, or Coanda effect, in a pulsatile flow field, and its impact on speech. The vocal folds form a divergent passage during phases of the phonation cycle when viscous effects such as flow separation are important. It was found that for divergence angles of less than 20 degrees, the attachment of the flow to the vocal-fold walls occurred when the acceleration of the forcing function was zero, and the flow had reached maximum velocity. For a divergence angle of 40 degrees, the fully separated central jet never attached to the vocal-fold walls. Inferences are made regarding the impact of the Coanda effect on the sound source contribution in speech.
منابع مشابه
Finite element model of the human phonation process
The basis of the human phonation process is given by complex interaction of air flow in the larynx together with structural mechanics of the vocal folds. This paper presents a numerical scheme to model the fluid-solid interaction in the human larynx and its resulting acoustic sound. The scheme is utilised to simulated the phonation process in a 2D-model. Different geometries of the vocal folds ...
متن کاملEffect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery
A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...
متن کاملStudy of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction
Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...
متن کاملAn implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery
With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...
متن کاملNumerical Study of Hemodynamic Wall Parameters on Pulsatile Flow through Arterial Stenosis
In this paper hemodynamic wall parameters which play an important role to diagnose arterial disease were studied and compared for three different rheology models (Newtonian, Power law and Quemada). Also because of the pulsatile behavior of blood flow the results were obtained for three Womersley numbers which represent the frequencies of the applied pulses. Results show that Quemada model alway...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 120 2 شماره
صفحات -
تاریخ انتشار 2006