A 13 channel 3 Tesla Shoulder Coil on a Domed Conformable Former
نویسندگان
چکیده
Introduction: MRI provides an essential tool for musculoskeletal radiology. The highest quality images are obtained with anatomically specific RF coil designs, customized to the anatomy of interest. The shoulder presents a difficult target, however, because of wide variations in body habitus and the difficulty of arranging coil elements around the shoulder to optimize sensitivity. The most commonly available shoulder coils consist of a rigid concave housing on which 4 to 8 receive elements are arranged. These provide high sensitivity in the rotator cuff region, but the sensitivity drops off steeply towards deeper tissue such as the glenoid cartilage and the labro-ligamentous anatomy. Flexible designs have also been described to accommodate different body sizes [1]. In this work, we design, build and test a novel shoulder array aiming to achieve higher SNR in deep tissue and improving parallel imaging performance in a flexible coil housing which can conform to a variety of body types.
منابع مشابه
An Optimized “QD-like” 6-Channel Flexible and Ergonomic Shoulder Array Coil at 1.5T
Shoulder anatomy size varies significantly when human weight changes from 120lb to more than 400 lb. This rather a huge “shoulder geometry” variation presents a technical challenge to shoulder coil design with respect to coverage and SNR, yielding a conventional approach where a large shoulder coil and a small shoulder coil are offered. Previous studies show that hinged surface coil gave a high...
متن کامل96-Channel receive-only head coil for 3 Tesla: design optimization and evaluation.
The benefits and challenges of highly parallel array coils for head imaging were investigated through the development of a 3T receive-only phased-array head coil with 96 receive elements constructed on a close-fitting helmet-shaped former. We evaluated several designs for the coil elements and matching circuitry, with particular attention to sources of signal-to-noise ratio (SNR) loss, includin...
متن کاملMultiple-Animal MR Imaging Performed using a 3-Tesla Whole-body Scanner: A Feasibility Study using a 16-Channel Array Coil
before (left) and after (right) signal intensity correction. The images of the other 2 rats were simultaneously obtained and were of comparable quality (not shown). Fig.1. Sixteen-channel coil dedicated for small animal MRI. An array comprises 8 5-cm-circular coils (a). The 16-channel coil has 2 sets of 8-array coils in the upper and lower parts (b). A white bar on the top is used to adjust the...
متن کاملA Specialized Multi-Transmit Head Coil for High Resolution fMRI of the Human Visual Cortex at 7T
PURPOSE To design, construct and validate radiofrequency (RF) transmit and receive phased array coils for high-resolution visual cortex imaging at 7 Tesla. METHODS A 4 channel transmit and 16 channel receive array was constructed on a conformal polycarbonate former. Transmit field efficiency and homogeneity were simulated and validated, along with the Specific Absorption Rate, using [Formula:...
متن کاملLocal Multi-Channel RF Surface Coil versus Body RF Coil Transmission for Cardiac Magnetic Resonance at 3 Tesla: Which Configuration Is Winning the Game?
INTRODUCTION The purpose of this study was to demonstrate the feasibility and efficiency of cardiac MR at 3 Tesla using local four-channel RF coil transmission and benchmark it against large volume body RF coil excitation. METHODS Electromagnetic field simulations are conducted to detail RF power deposition, transmission field uniformity and efficiency for local and body RF coil transmission....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010