Electrocautery-induced pacemaker malfunction during surgery.
نویسندگان
چکیده
We report a case of electrocautery-induced pacemaker failure that resulted in asystole in a 15-year-old girl scheduled for cardiac surgery. Her pacemaker was converted to the asynchronous mode the night before surgery. Electromagnetic interference from the unipolar electrocautery caused a reduction in the battery voltage, which allowed the digital circuitry, but not the voltage control oscillator (VCO), to work properly. Eventually the battery current drain caused VCO "lock-out," and pacemaker and battery failure. This report demonstrates that electrocautery-induced pacemaker failure can occur, even after conversion to asynchronous mode.
منابع مشابه
Ventricular fibrillation induced by coagulating mode bipolar electrocautery during pacemaker implantation in Myotonic Dystrophy type 1 patient
The occurrence of ventricular fibrillation, induced by bipolar electrocautery during elective dual chamber pacemaker implantation, is reported in a patient affected by Myotonic Distrophy type 1 with normal left ventricular ejection fraction.
متن کاملElectromagnetic interference in a cardiac pacemaker during cauterization with the coagulating, not cutting mode
Electromagnetic interference in pacemakers has almost always been reported in association with the cutting mode of monopolar electrocautery and rarely in association with the coagulation mode. We report a case of electrocautery-induced electromagnetic interference with a DDDR pacemaker (dual-chamber paced, dual-chamber sensed, dual response to sensing, and rate modulated) in the coagulating and...
متن کاملPii: S1010-7940(02)00020-9
Electrocautery has a potential risk of serious pacemaker dysfunction in patients with implanted pacemaker. Here we present the safe and efficient use of ultrasonic scalpel (Harmonic scalpel) for the first time in a patient with implanted pacemaker undergoing open-heart reoperation. q 2002 Elsevier Science B.V. All rights reserved.
متن کاملPacemaker and ICD generator reliability: meta-analysis of device registries.
CONTEXT Despite there being millions of pacemaker and implantable cardioverter-defibrillator (ICD) generator implants worldwide, little is known about device reliability. OBJECTIVES To perform a meta-analysis of prospective pacemaker and ICD registries to determine annual rates of pacemaker and ICD malfunction and to identify trends in these rates. DATA SOURCES MEDLINE (January 1966 to Apri...
متن کاملElectrocautery-induced airway fire during tracheostomy.
Although most of the recent attention regarding airway fires has focused on the intraoperative use of the laser, it is important to remember that electrocautery may also serve as a source of ignition during surgery involving the airway and/or oropharyngeal cavity. This subject is mentioned in only a handful of isolated reports in the recent literature (1-3). The following is, we believe, the fi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Canadian journal of anaesthesia = Journal canadien d'anesthesie
دوره 38 5 شماره
صفحات -
تاریخ انتشار 1991