Single-centre experience with coronary sinus lead stability and long-term pacing parameters.

نویسندگان

  • Alan Bulava
  • Jan Lukl
چکیده

AIMS To compare both short- and long-term stability and pacing parameters of CS leads. Long-term maintenance of coronary sinus (CS) pacing lead position has not yet been assessed by serial X-ray digital imaging. METHODS AND RESULTS Using X-ray digital imaging in anteroposterior and left lateral views, we performed analysis of the CS lead position at the end of the implantation procedure, 48 h following implantation and after 12 months in 93 consecutive patients. Attain OTW leads, QuickSite leads and EasyTrak leads were implanted in 44, 12 and 37 cases, respectively. X-ray detectable late CS lead dislodgement was observed in 8 cases (8.6%) during 12-months follow-up. Dislodgment was once accompanied by loss of capture and need for repositioning. Another two major dislodgements occurred without any threshold change. Five (5.4%) minor dislocations occurred with either a decrease or an increase in pacing threshold. Left ventricular (LV) pacing threshold was changed by >or= 1 V after 12 months in 14 patients (15%) when compared to values 48 h after implantation. All but one case of >or= 1 V threshold change (either positive or negative) occurred without any radiological evidence of lead displacement. LV pacing threshold was significantly higher than RV pacing threshold at both baseline and during follow-up. Leads from all three manufacturers had comparable pacing thresholds 12 months following implantation. CONCLUSION The position of CS leads may change during 1-year follow-up. However, it rarely required reoperation in the selected group of patients. Long-term pacing parameters between different manufacturers are comparable. Increase in pacing threshold is not a reliable marker of CS lead dislodgement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term outcome of patients with drug-refractory atrial flutter and fibrillation after single- and dual-site right atrial pacing for arrhythmia prevention.

OBJECTIVES An initial crossover study comparing dual- and single-site right atrial pacing was performed followed by a long-term efficacy and safety evaluation of dual-site right atrial pacing in patients with drug-refractory atrial fibrillation (AF). Also examined was the efficacy of two single-site right atrial pacing modes (high right atrium and coronary sinus ostium) and the long-term need f...

متن کامل

Diagnostic and therapeutic uses of atrial pacing.

There are occasions when atrial pacing can be usefully employed both diagnostically and therapeutically. Diagnostically, atrial pacing provides mechanisms for easily, safely, and reproducibly stressing the heart that can help in the evaluation of patients with a variety of cardiac disorders. It is particularly useful in the assessment of patients with coronary disease. Therapeutically, atrial p...

متن کامل

Acute and chronic performance evaluation of a novel epicardial pacing lead placed by percutaneous subxiphoid approach in a canine model.

BACKGROUND Endovascularly implanted leads risk vascular injury and endocarditis, and can be difficult to locate in desired positions for LV pacing. We evaluated the acute and long-term stability, electric performance and histopathology of a percutaneously placed intrapericardial lead (IPL). METHODS AND RESULTS Twelve adult mongrel dogs underwent defibrillator implants incorporating IPLs. Succ...

متن کامل

Immediate and mid-term safety and efficacy of single lead VDD pacemakers for patients with atrioventricular block and normal sinus node function--a single centre experience.

INTRODUCTION Single lead atrial synchronous ventricular pacing (VDD) is increasingly being used in place of conventional dual chamber pacing (DDD) for patients with atrioventricular block and preserved sinus node function. Compared to the latter, VDD pacemakers provide similar haemodynamic benefits derived from atrial synchronous pacing, with the added benefit of an easier implant procedure. ...

متن کامل

Requirement for coronary sinus lead interventions and effectiveness of endovascular replacement during long-term follow-up after implantation of a resynchronization device.

AIMS The aim of this study was to assess the requirement for coronary sinus (CS) lead intervention after cardiac resynchronization therapy (CRT) and to evaluate the effectiveness of endovascular replacement. METHODS AND RESULTS All patients receiving a CRT device with CS lead in the Leiden University Medical Center in the period from 1999 to 2007 were prospectively evaluated and followed. Fiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 9 7  شماره 

صفحات  -

تاریخ انتشار 2007