Biomechanical comparison of first metatarsophalangeal joint arthrodeses using triple-threaded headless screws versus partially threaded lag screws.

نویسندگان

  • Kurt J Lucas
  • Randal P Morris
  • William L Buford
  • Vinod K Panchbhavi
چکیده

BACKGROUND Triple-threaded, cannulated headless screws of varying thread diameters and pitch are designed to maintain thread length across the arthrodesis plane, provide joint compression, and reduce countersinking. This study tested the biomechanical fixation strength of conventional partially threaded lag screws compared to triple-threaded headless screws in first metatarsophalangeal joint arthrodesis. METHODS First metatarsophalangeal joint arthrodesis using a crossed screw technique was performed on 11 paired, preserved cadaver first rays with two 4.0-mm triple-threaded, cannulated headless screws or two 4.0-mm partially threaded, cannulated lag screws. The constructs were tested to failure through dorsally directed cantilever bending. RESULTS The triple-threaded, cannulated headless screws displayed significantly greater bending stiffness (p=0.017) and failure load (p=0.040) during load-to-failure testing compared to the partially threaded, cannulated lag screws. CONCLUSIONS Triple-threaded, cannulated headless screws may be a viable alternative to partially threaded lag screws in first metatarsophalangeal arthrodesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

Biomechanical Comparison of Inter-fragmentary Compression Pressures: Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation

OBJECTIVE The purpose of the present study was to compare inter-fragmentary compression pressures after fixation of a simulated type II odontoid fracture with the headless compression Herbert screw and a half threaded cannulated lag screw. METHODS We compared inter-fragmentary compression pressures between 40- and 45-mm long 4.5-mm Herbert screws (n=8 and n=9, respectively) and 40- and 45-mm ...

متن کامل

Epiphysiodesis Screw Bending.

Percutaneous epiphysiodesis using transphyseal screws is a common method for treatment of limb length discrepancy and angular deformity. The authors report 3 cases of a previously unreported complication following treatment with percutaneous epiphysiodesis using transphyseal screws: bending of the transphyseal screw. In each case, this rare complication was associated with difficult removal of ...

متن کامل

Laboratory comparison of the cannulated Herbert bone screw with ASIF cancellous lag screws.

The compression produced by and the resistance to pullout of the 6.5 mm cannulated Herbert screw were compared with those of ASIF headed screws. The latter were tested with and without washers and in the following sizes: 4.5 mm cortical, 6.5 mm cancellous with a 16 mm threaded segment, and 6.5 mm cancellous with a 32 mm threaded segment. Polyurethane foam was used as a substitute for cancellous...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons

دوره 20 2  شماره 

صفحات  -

تاریخ انتشار 2014