Quality in Diagnostic Microbiology: Experiential Note to Emphasize Value of Internal Control Programs

نویسنده

  • Ezekiel Uba Nwose
چکیده

BACKGROUND Quality control (QC) in diagnostic microbiology is a matter of effective, efficient, accurate reporting in the expected turnaround time. Major stages of the analytical "standard operational procedures" where QC could be easily affected include organism identification and antibacterial susceptibility testing. AIM The objective of this experiential technical note is to provide an evidence base to highlight the value of internal QC program in evaluating the effectiveness and efficiency of a laboratory's standard operational procedures; and the competences of individual scientific/technical staff. MATERIALS AND METHODS This report is based on four different scenarios requiring internal QC, including cases that are not reported within the turnaround time of standard operational procedures. Small-scale evaluations of (i) internal QC program, (ii) ciprofloxacin vs. moxifloxacin susceptibilities, and (iii) calibrated dichotomous susceptibility vs. directed susceptibility testing were performed. RESULTS The internal QC program identified sources of discrepancies in laboratory results. Evidence base for decision on new methodology and antibiotic testing were developed. For instance, it is observed that calibrated dichotomous susceptibility gives greater annular radius than directed susceptibility (P < 0.01). CONCLUSIONS Internal QC program continues to be valuable means of identifying discrepancies, and vetting new ideas. This report presents evidence base to reaffirm that the need for internal QC is ever present.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality Control Assessment of Conventional Radiology Devices in Iran

Introduction Quality control (QC) techniques are used in monitoring and maintenance of the components of an x-ray system. QC of radiology devices plays a significant role in reduction of medication dose and optimization of image quality. This study aimed to conduct QC tests on randomly selected radiology devices, installed in diagnostic imaging departments of Iran. Materials and Methods In tota...

متن کامل

Quality Control Assessment of Radiology Devices in Kerman Province, Iran

Introduction Application of quality control (QC) programs at diagnostic radiology departments is of great significance for optimization of image quality and reduction of patient dose. The main objective of this study was to perform QC tests on stationary radiographic X-ray machines, installed in 14 hospitals of Kerman province, Iran. Materials and Methods In this cross-sectional study, QC tests...

متن کامل

Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

متن کامل

Quality control for diagnostic oral microbiology laboratories in European countries

Participation in diagnostic microbiology internal and external quality control (QC) processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB) Network was created. At the European Oral Microbiology Workshop in 2008, 12 laboratories processing...

متن کامل

Diagnostic reference levels at intraoral and dental panoramic examinations

Background: The aim of this study was to measure and determine diagnostic reference levels (DRLs) of programs used at intraoral and dent panoramic examinations in Kosovo. Materials and Methods: To determine DRL, were performed measurements for dose area product (DAP) at intraoral and dental panoramic radiology systems. This study has covered over 47% of X-ray units, which are in use for intraor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2013