Fragment assembly with double-barreled data

نویسندگان

  • Pavel A. Pevzner
  • Haixu Tang
چکیده

For the last twenty years fragment assembly was dominated by the "overlap - layout - consensus" algorithms that are used in all currently available assembly tools. However, the limits of these algorithms are being tested in the era of genomic sequencing and it is not clear whether they are the best choice for large-scale assemblies. Although the "overlap - layout - consensus" approach proved to be useful in assembling clones, it faces difficulties in genomic assemblies: the existing algorithms make assembly errors even in bacterial genomes. We abandoned the "overlap - layout - consensus" approach in favour of a new Eulerian Superpath approach that outperforms the existing algorithms for genomic fragment assembly (Pevzner et al. 2001 InProceedings of the Fifth Annual International Conference on Computational Molecular Biology (RECOMB-01), 256-26). In this paper we describe our new EULER-DB algorithm that, similarly to the Celera assembler takes advantage of clone-end sequencing by using the double-barreled data. However, in contrast to the Celera assembler, EULER-DB does not mask repeats but uses them instead as a powerful tool for contig ordering. We also describe a new approach for the Copy Number Problem: "How many times a given repeat is present in the genome?". For long nearly-perfect repeats this question is notoriously difficult and some copies of such repeats may be "lost" in genomic assemblies. We describe our EULER-CN algorithm for the Copy Number Problem that proved to be successful in difficult sequencing projects.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hydrophobic Coupling of Lipid Bilayer Energetics to Channel Function

The hydrophobic coupling between membrane-spanning proteins and the lipid bilayer core causes the bilayer thickness to vary locally as proteins and other "defects" are embedded in the bilayer. These bilayer deformations incur an energetic cost that, in principle, could couple membrane proteins to each other, causing them to associate in the plane of the membrane and thereby coupling them functi...

متن کامل

Specialist Review Algorithmic challenges in mammalian whole-genome assembly

The basic methodology used today for sequencing a large genome is doublebarreled shotgun sequencing. Shotgun sequencing, introduced by Sanger and colleagues early on (Sanger et al ., 1977), involves obtaining a redundant representation of a genomic segment with sequenced reads and then assembling the reads into contigs on the basis of sequence overlap. Double-barreled shotgun sequencing enhance...

متن کامل

The double-barreled radial forearm osteocutaneous free flap.

OBJECTIVES/HYPOTHESIS The radial forearm osteocutaneous free flap (RFOCFF) provides a thin pliable skin paddle with up to 11 cm of bone. A limitation of this flap is the thin bone that is obtained and the lack of suitability for dental implants. A minimum depth of 5 mm and height of 10 mm is required for a bony flap to accept osteointegrated implants. We propose that by double barreling the rad...

متن کامل

Revisiting the double-barreled wet colostomy for simultaneous urinary and fecal diversion--an Indian experience.

Pelvic exenteration in advanced malignancies is usually a curative procedure aimed at improving quality of life. We analyzed the perioperative data and outcomes in 12 patients who underwent simultaneous urinary and fecal diversion with a double-barreled wet colostomy after total pelvic exenteration. Eight males and four females aged between 25 and 73 years underwent the procedure with mean oper...

متن کامل

Simultaneous Measurement of Intracellular pH and K+ or NO3- in Barley Root Cells Using Triple-Barreled, Ion-Selective Microelectrodes.

The manufacture and use of triple-barreled microelectrodes, which are capable of simultaneous in vivo measurement of intracellular pH and the activities of K+ or NO3- and cell membrane potential (Em), are described. Scanning electron micrographs showed that the three tips were aligned and that the overall tip diameter was approximately 0.8 [mu]m. When filled with 100 mM KCl, all three barrels s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Bioinformatics

دوره 17 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2001