Ultrastructural and histopathologic findings after pars plana vitrectomy with a new hypersonic vitrector system. Qualitative preliminary assessment

نویسندگان

  • Salvador Pastor-Idoate
  • Richard Bonshek
  • Luciane Irion
  • Isaac Zambrano
  • Paul Carlin
  • Aleksandr Mironov
  • Paul Bishop
  • David McLeod
  • Paulo Eduardo Stanga
چکیده

PURPOSE Preliminary assessment of a new prototype ultrasound-based hypersonic vitrector (HV) by qualitatively examining the histopathological changes in the retina and vitreous body after pars plana vitrectomy (PPV) and its ability to fragment vitreous collagen. METHODS Fourteen porcine cadaveric eyes, 20 eyes in live swine and six human cadaveric eyes underwent PPV using the HV or a pneumatic guillotine vitrector (GV). An additional 4 porcine crystalline lenses were touched with either the HV or GV for 1 minute. Following PPV, human vitreous was removed and processed for electron microscopy (EM). Eyes and lenses were fixed and sectioned for light microscopy (LM). RESULTS There were no macroscopic retinal or optic nerve defects associated with either HV or GV PPVs. Cadaveric retinal specimens showed separation of the inner limiting membrane (ILM) and vacuolization and fragmentation at the nerve fiber layer (NFL) and the ganglion cell layer (GCL). ILM fragmentation and separation were found after PPV in live swine with both vitrectors. Small disruptions of the posterior capsule or structural lens defects were found after HV touch. The EM analysis revealed more fragmentation of human vitreous collagen fibrils after HV compared to GV PPV. CONCLUSIONS LM and EM analysis of retina, vitreous, and crystalline lens after PPV showed similar morphological changes using the HV or the GV. Vitreous fragmentation appeared more effective with the HV. Overall this study suggests that the HV may be a promising new technology. More work is needed to quantitatively assess its safety and efficacy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance analysis of a new hypersonic vitrector system

PURPOSE To evaluate porcine vitreous flow and water flow rates in a new prototype hypersonic vitrectomy system compared to currently available pneumatic guillotine vitrectors (GVs) systems. METHODS Two vitrectors were tested, a prototype, ultrasound-powered, hypersonic vitrector (HV) and a GV. Porcine vitreous was obtained within 12 to 24 h of sacrifice and kept at 4°C. A vial of vitreous or ...

متن کامل

Micro Incision Vitrectomy Surgery (MIVS): An Overview

Introduction In today’s world of nano-technology where bigger no longer means better, everything from smartphones to surgical incisions are getting smaller and more refined. The advantages of smaller surgical incision have resulted in faster postoperative recovery. Vitreoretinal surgery is no exception. We have come a long way since the time of open sky vitrectomy and Machemer’s first 17-gauge ...

متن کامل

Modified Curved Aspiration Cannulas and End-gripping Forceps for 25-gauge Vitrectomy on Highly Myopic Eyes

Pars plana vitrectomy in highly myopic eyes with an axial length (AL) of over 27.00 mm using instruments with the standard length is more challenging than surgery on eyes with an average length of 22.00 mm to 24.00 mm. One of the most difficult maneuvers is to reach the posterior pole of the eye, especially in the case of posterior staphyloma. To reach the posterior retina, the long AL of myopi...

متن کامل

Two cases of malignant glaucoma unresolved by pars plana vitrectomy

Malignant glaucoma, which is characterized by a shallow or flat anterior chamber with high intraocular pressure, can usually be resolved by pars plana vitrectomy with anterior hyaloidectomy. We describe two cases in which malignant glaucoma was refractory to conventional treatment and complete vitrectomy. Case one an 88-year-old woman with pseudoexfoliation glaucoma underwent trabeculotomy and ...

متن کامل

A case of 25 gauge vitrectomy for malignant glaucoma with microphthalmos

UNLABELLED We report the first case report of pars plana lensectomy (PPL) and pars plana vitrectomy using a 25 gauge vitrectomy system for microphthalmos. RESULTS A 45-year-old woman reported repeated pain in her left eye, despite the use of medications. Ultrasound biomicroscopy revealed a narrow angle and thickened sclera. The lens and the iris showed anterior displacement with a flattening ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017