Short-term Outcomes of Ceramic Coated Metal-on-Metal Large Head in Total Hip Replacement Arthroplasty

نویسندگان

  • Weon-Yoo Kim
  • Myung-Sup Ko
  • Se-Won Lee
  • Kwang-Sub Kim
چکیده

Purpose This study characterizes the short-term outcomes of ceramic coated metal-on-metal (MoM) large head total hip arthroplasty (THA) in prospectively selected patients aged 70 to 75 years. Materials and Methods Eighteen patients (18 hips) between the ages of 70 and 75-years old with THA using ceramic-coated MoM large heads between June 2014 and December 2014 were evaluated. We prospectively selected patients younger than 70 years for bipolar hemiarthroplasty and older than 75 years for conventional THA. There were one case of osteoarthritis, 8 cases of femur neck fracture, and 9 cases of intertrochanteric fracture. All patients underwent clinical and radiological follow-up at 6 weeks, 6 and 12 months, and every year postoperatively. The mean duration of follow-up was 24.2 months (range, 18-34 months). Results The average Harris hip score at the final follow-up was 81.0, except one case which was ultimately converted to conventional THA due to acetabular cup loosening. Radiographically, mean acetabular cup inclination was 45.8°(range, 38-56°) and anteversion was 20.1° (range, 11-25°). The average femoral head size was 48.7 mm. All stems were neutral-positioned except 1 varus-positioned stem. There was 1 case of a soft tissue infection, 3 patients complained of persistent groin pain, and no dislocations occurred. Conclusion Ceramic coated large MOM articulation (ACCIS) have many complications: cup loosening, groin pain, which can lead to fatal outcomes in the elderly patients. Especially in patients with communicated intertrochanter fracture (AO 31-A22, 23), careful attention should be paid to the choice of surgical option.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

Fatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty

This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA). After diagnosing a fractured ceramic liner, the hip prosthesis was revised into a metal-on-polyethylene bearing. At one year...

متن کامل

Comparative effectiveness of ceramic-on-ceramic implants in stemmed hip replacement: a multinational study of six national and regional registries.

BACKGROUND The rapid decline in use of conventional total hip replacement with a large femoral head size and a metal-on-metal bearing surface might lead to increased popularity of ceramic-on-ceramic bearings as another hard-on-hard alternative that allows implantation of a larger head. We sought to address comparative effectiveness of ceramic-on-ceramic and metal-on-HXLPE (highly cross-linked p...

متن کامل

Metallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component

The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a m...

متن کامل

The Epidemiology of Total Hip Arthroplasty Bearing Surface Use in the United States

Introduction: Metal on conventional ultra-high molecular weight polyethylene (UHMWPE) bearings have produced excellent long-term results in total hip arthroplasty (THA), with 20 year survivorship of almost 80%. However, the consequences of bearing surface wear, including osteolysis and aseptic loosening, have been a leading cause of late revision THA, especially in younger, more active patients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2018