Clinical applications of gas chromatograph/mass spectrometer/computer systems.
نویسندگان
چکیده
Gas chromatograph/mass spectrometer/computer systems can be used to quantify a wide variety of compounds of clinical interest. A quadrupole instrument operated in the chemical ionization (Cl) mode was used in these studies. Because of the sensitivity and specificity of selective ion detection, it is possible to make measurements routinely in the nanogram to picogram range, with 0.1-1.0 ml samples of plasma and 1-5 ml samples or urine. Internal standards, preferably stable-isotope-labeled compounds, were added to the biological samples before isolation was begun. We describe clinical applications of these procedures to problems in toxicology, pharmacokinetics, and perinatal pharmacology.
منابع مشابه
Evaluation of a benchtop capillary gas chromatograph-mass spectrometer for clinical toxicology.
We evaluated the Hewlett-Packard 5995B benchtop capillary gas chromatograph-mass spectrometer (GC-MS) for its ability to identify drugs commonly detected and (or) measured in the clinical toxicology laboratory. Initial experiments indicated that the instrument as originally configured, with an isolation valve between the gas chromatograph and mass spectrometer, was unsatisfactory for the identi...
متن کاملDerivatization in mass spectrometry --7. On-line derivatisation/degradation.
The review describes on-line derivatization/degradation methods employed in mass spectrometry to solve some structural and analytical problems. Advantages and applications of various positions of reaction systems connected mainly to a mass spectrometer or a gas chromatograph/mass spectrometer are considered. Among these are reaction systems connected directly to the mass spectrometer (reaction ...
متن کاملVolatile carboxylic acid profiling in physiological fluids: direct injection into a gas chromatograph/mass spectrometer.
We present a procedure for the profiling of the volatile carboxylic acids and neutral compounds in blood or urine using the direct injection of the acidified sample into a gas chromatograph interfaced with a mass spectrometer by a jet separator. The non-volatile components remain at the head of the SP-1000 column while the volatile components move through the column. Up to sixty physiological s...
متن کاملFlexible data handling for routine quantitative analyses employing a gas chromatograph-mass spectrometer under computer control
متن کامل
Methylene unit calibration for analysis of organic acids by gas--liquid chromatography/mass spectrometry.
We describe a method for automatic computation of "methylene unit" retention-time indices in real time on a computer-controlled gas chromatograph/mass spectrometer system. The calculation is based on the exponential relationship between the methylene unit values of hydrocarbon reference standards and the oven temperature at their elution. Using this mathematical relationship, we calculated cali...
متن کاملذخیره در منابع من