Impact of Preparation Phases on Vessel Wall Imaging Using Spiral Image Acquisition at 3 Tesla

نویسندگان

  • M. W. Lagemaat
  • M. Henningsson
  • P. Boernert
  • J. Smink
  • A. J. Wiethoff
  • R. M. Botnar
چکیده

Introduction: Coronary vessel wall imaging with MR has the ability to obtain vessel wall thickness and lumen d invasively (1,2,3). Apart from cardiac and respiratory motion, a major challenge of coronary vessel wall imaging is th small thickness (0.5-2mm) and thus the need for high resolution. With the wider spread availability of high field 3T clin higher resolution coronary vessel wall imaging has become more feasible. A previous pilot study using a 3T system gain in SNR of about 50% compared with results obtained at 1.5T (4). The use of more SNR-efficient spiral sequen with the local inversion technique would combine the advantage of high field MRI with the ability of 3D imaging of vessel wall. The main challenge to be overcome is the increased field inhomogeneity (∆f0) at 3T, which especially may use of spiral imaging due to its sensitivity to off-resonances. Therefore the preparation phases for determining the c shim values are of high importance. In particular, f0 may also vary throughout the cardiac and respiratory cycle, requir shimming and f0 determination. In this study we sought to optimize the local inversion pre-pulse technique togethe image acquisition for 3T systems and investigated the impact of the f0 and shimming trigger delay on image qua investigated the effects of small long-term drifts in the magnet field strength that may affect fat sat (SPIR) per performing a f0 shift calibration during the preparation phase.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose

Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...

متن کامل

High resolution 3D spiral coronary vessel wall imaging with >99% respiratory efficiency using beat to beat respiratory motion correction: quantitative comparison with navigator gated 2D spiral and turbo spin echo imaging

Introduction: Dark blood coronary artery wall imaging has demonstrated the ability to detect vessel wall thickening in subjects with non-significant coronary heart disease [1]. For high resolution imaging, studies are generally performed with diaphragmatic navigator gating which has an inherently low respiratory efficiency (RE) and is further compromised by respiratory drift through the long ac...

متن کامل

Comparison of different data acquisition strategies in myocardial strain assessment using strain-encoded (SENC) MRI

Introduction: Strain-encoding (SENC) MRI was recently introduced for measuring myocardial through-plane strain with high resolution and simple post-processing (1). Figure 1 shows the SENC pulse sequence. In a typical sequence, k-space data is acquired line by line in a rectilinear fashion, which results in long scan time and renders the technique impractical in many applications. Nevertheless, ...

متن کامل

Reproducibility of coronary vessel wall imaging techniques

Background Coronary wall thickness measurements must be highly reproducible to be useful in longitudinal studies. While 2D turbo-spin-echo (TSE) and spiral techniques are commonly used, 3D techniques reduce partial-volume effects and allow greater vessel coverage. Recently, 3D coronary wall imaging was demonstrated with 100% respiratory efficiency (RE) using beat-to-beat respiratory motion corr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008