Hamstring tendon grafts for reconstruction of the anterior cruciate ligament: biomechanical evaluation of the use of multiple strands and tensioning techniques.

نویسندگان

  • D L Hamner
  • C H Brown
  • M E Steiner
  • A T Hecker
  • W C Hayes
چکیده

BACKGROUND Our hypothesis that multiple, equally tensioned strands of hamstring graft used for reconstruction of the anterior cruciate ligament are stronger and stiffer than ten-millimeter patellar ligament grafts was tested biomechanically with use of tendons from cadavera. METHODS In the first part of the study, we measured the strength and stiffness of one, two, and four-strand hamstring grafts, from fresh-frozen cadaveric knees, that had been tensioned equally when clamped. In the second part of the study, we compared four-strand grafts to which tension had been applied by hand and then clamped with similar grafts to which tension had been applied with weights and then clamped. The grafts for the two experiments were obtained from thirty-four paired and ten unpaired knees. We also studied the effects of cooling on the biomechanical properties of grafts by comparing patellar ligament grafts tested at 13 degrees Celsius with those tested at room temperature. RESULTS Two equally tensioned gracilis strands had 185 percent of the strength and 210 percent of the stiffness (1550+/-428 newtons and 336+/-141 newtons per millimeter, respectively) of one gracilis strand (837+/- 138 newtons and 160+/-44 newtons per millimeter, respectively). Two equally tensioned semitendinosus strands had 220 percent of the strength and 220 percent of the stiffness (2330+/-452 newtons and 469+/-185 newtons per millimeter, respectively) of one semitendinosus strand (1060+/-227 newtons and 213+/-44 newtons per millimeter, respectively). Four combined strands (two gracilis strands and two semitendinosus strands) that were equally tensioned with weights and clamped had the additive tensile properties of the individual strands. With the numbers available, four combined strands that were manually tensioned and clamped were not found to be significantly stronger or stiffer than two semitendinosus strands that were equally tensioned with weights (p>0.07). CONCLUSIONS Four combined strands that were equally tensioned with weights and clamped were stronger and stiffer than all ten-millimeter patellar ligament grafts that have been described in previous reports. All strands of a hamstring graft must be equally tensioned for the composite to have its optimum biomechanical properties. CLINICAL RELEVANCE Because of the well recognized donor-site morbidity associated with the use of patellar ligament grafts for reconstruction of the anterior cruciate ligament, multiple-strand hamstring-tendon grafts have become an increasingly popular choice. Our data demonstrate that equally tensioned four-strand hamstring-tendon grafts have initial tensile properties that are higher than those reported for ten-millimeter patellar-ligament grafts; thus, from a biomechanical point of view, they seem to be a reasonable alternative.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Twisting and braiding reduces the tensile strength and stiffness of human hamstring tendon grafts used for anterior cruciate ligament reconstruction.

BACKGROUND Twisting and braiding of four-strand hamstring tendon grafts used for anterior cruciate ligament reconstruction has been proposed, but not proven, as a method of improving tensile properties. HYPOTHESIS Twisting and braiding four-strand human hamstring tendon grafts will have no significant effect on initial graft strength or stiffness. STUDY DESIGN Paired in vitro biomechanical ...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Multistranded hamstring tendon graft fixation with a central four-quadrant or a standard tibial interference screw for anterior cruciate ligament reconstruction.

BACKGROUND Tibial fixation of hamstring tendon grafts has been the weak link in anterior cruciate ligament reconstruction. HYPOTHESIS Use of a central four-quadrant sleeve and screw provides superior fixation when compared with standard interference screw fixation. STUDY DESIGN Controlled laboratory study. METHODS In eight pairs of cadaveric knees each anterior cruciate ligament was recon...

متن کامل

0296 - the Mechanical Properties of Braided Tendon Grafts for Use in Acl Reconstruction

Introduction Controversy surrounds reconstruction of the anterior cruciate ligament (ACL) with regards to graft choice and fixation. Most surgeons performing ACL reconstruction use an intra-articular autogenous graft from either the patellar tendon or hamstrings. It has been suggested that hamstring tendon grafts are weaker than patellar tendon grafts, although there is conflicting data where m...

متن کامل

Principles for using hamstring tendons for anterior cruciate ligament reconstruction.

The use of autogenous hamstring tendon as a graft source for anterior cruciate ligament (ACL) reconstruction continues to gain in popularity. The low harvest morbidity and excellent biomechanical graft properties coupled with improved fixation of soft tissue grafts are all reasons for excellent clinical outcomes of ACL reconstruction using hamstring tendons. In addition, surgeon awareness of th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 81 4  شماره 

صفحات  -

تاریخ انتشار 1999