Precision Calibration of the DØ HCAL in Run II
نویسنده
چکیده
Most of the physics analyses at a hadron collider rely on a precise measurement of the energy of jets in the final state. This requires a precise in situ calibration of the calorimeter with the final detector setup. We present the basic procedure and results of the in situ gain calibration of the D0 HCAL in Run II. The gain calibration works on top of the pulser-based calibration of the readout electronics and is based entirely on collision data.
منابع مشابه
Combination of CDF and DØ Results on the Mass of the Top Quark The Tevatron Electroweak Working Group 1 for the CDF and DØ Collaborations
We summarize the top-quark mass measurements from the CDF and DØ experiments at Fermilab. We combine published Run-I (1992-1996) measurements with the most recent preliminary Run-II (2001-present) measurements using up to 750 pb −1 of data. Taking correlated uncertainties properly into account the resulting preliminary world average mass of the top quark is M t = 172.5 ± 1.3(stat) ± 1.9(syst) G...
متن کامل/ 02 10 00 2 v 1 3 0 Se p 20 02 1 The DØ Detector for Run II
The general purpose DØ collider detector at the Fermilab Tevatron has undergone major upgrades for Run II. We describe the current status and performance of the DØ detector.
متن کاملCombination of CDF and DØ Results on the Mass of the Top Quark
We summarize the top-quark mass measurements from the CDF and DØ experiments at Fermilab. We combine published Run-I (1992-1996) measurements with the most recent preliminary Run-II (2001-present) measurements using up to 750 pb −1 of data. Taking correlated uncertainties properly into account the resulting preliminary world average mass of the top quark is M t = 172.5 ± 1.3(stat) ± 1.9(syst) G...
متن کاملRecent Dø Results at Run Ii
The DØ experiment is taking data with an upgraded detector since March 2001. The integrated luminosity taken in Run II has now exceeded that taken in Run I. Selected physics results obtained with this data set are presented.
متن کاملDØ Upgrade for RUN II
The DØ detector at The Fermilab Tevatron is undergoing a major upgrade to prepare for data taking with luminosities reaching 2× 10 cm s. The upgrade includes a new central tracking array, new muon detector components and electronic upgrades to many subsystems. The DØ upgraded detector will be operational for RUN II in spring 2000.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006