Total Hip Arthroplasty with Biomec Prosthesis: 20-year Follow-up.
نویسندگان
چکیده
OBJECTIVE To analyze the clinical and radiological outcomes from total hip arthroplasty using the Biomec prosthesis over a 20-year period (1988 to 2009). METHODS The patients were evaluated clinically in accordance with the Merle d'Aubigné and Postel functional classification, and underwent anteroposterior (AP) radiography of the pelvis and the operated joint in lateral view. The variables evaluated were acetabular and femoral osteolysis, polyethylene wear, nail migration, follow-up and clinical outcomes. RESULTS The mean follow-up was 10.6 years (range 4 to 21 years). The sample consisted of 84 patients (32 men and 52 women) and the mean preoperative age was 47 years. We found that 88% of the results from the clinical evaluation were good or excellent. In relation to the radiological findings, 92.5% of the results were good. The mean wear on the polyethylene was 1.4 mm. CONCLUSION The use of the Biomec prosthesis in this cohort showed good clinical and radiographic results.
منابع مشابه
Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملMinimum Seven-year Follow-up of Cementless Total Hip Arthroplasty with the COREN Hip System
Total hip arthroplasty (THA) is currently one of the most widely performed procedures in orthopedic practice. Over recent years, THA gained much improvement in terms of prosthesis design, availability of suitable component materials and manufacturing techniques, and a better understanding of hip mechanics. In a previous study, we reported results at a mean 3.2 years following implantation of th...
متن کاملCementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملRevision of failed hip resurfacing to total hip arthroplasty rapidly relieves pain and improves function in the early post operative period
We reviewed the results of 25 consecutive patients who underwent revision of a hip resurfacing prosthesis to a total hip replacement. Revisions were performed for recurrent pain and effusion, infection and proximal femoral fractures. Both components were revised in 20 cases.There were 12 male and 13 female patients with average time to revision of 34.4 and 26.4 months respectively. The mean fol...
متن کاملLong Term Outcomes of Total Hip Arthroplasty in Young Patients under 30
Background: We aimed to report outcomes of total hip arthroplasty (THA) in very young patients under the year of 30. Methods: Thirty patients (45 hips) with various indications for THA were retrospectively reviewed radiologically and clinically and analyzed regarding survival, reasons of failure, factors associated with outcomes and postoperative complications. Results: Within a mean fol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista brasileira de ortopedia
دوره 45 2 شماره
صفحات -
تاریخ انتشار 2010