Impact of iterative reconstruction vs. filtered back projection on image quality in 320-slice CT coronary angiography
نویسندگان
چکیده
Iterative reconstruction has been shown to reduce image noise compared with traditional filtered back projection with quantum denoising software (FBP/QDS+) in CT imaging but few comparisons have been made in the same patients without the influence of interindividual factors. The objective of this study was to investigate the impact of adaptive iterative dose reduction in 3-dimensional (AIDR 3D) and FBP/QDS+-based image reconstruction on image quality in the same patients.We randomly selected 100 patients enrolled in the coronary evaluation using 320-slice CT study who underwent CT coronary angiography using prospectively electrocardiogram triggered image acquisition with a 320-detector scanner. Both FBP/QDS+ and AIDR 3D reconstructions were performed using original data. Studies were blindly analyzed for image quality by measuring the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Image quality was assessed qualitatively using a 4-point scale.Median age was 63 years (interquartile range [IQR]: 56-71) and 72% were men, median body mass index 27 (IQR: 24-30) and median calcium score 222 (IQR: 11-644). For all regions of interest, mean image noise was lower for AIDR 3D vs. FBP/QDS+ (31.69 vs. 34.37, P ≤ .001). SNR and CNR were significantly higher for AIDR 3D vs. FBP/QDS+ (16.28 vs. 14.64, P < .001 and 19.21 vs. 17.06, P < .001, respectively). Subjective (qualitative) image quality scores were better using AIDR 3D vs. FBP/QDS+ with means of 1.6 and 1.74, respectively (P ≤ .001).Assessed in the same individuals, iterative reconstruction decreased image noise and raised SNR/CNR as well as subjective image quality scores compared with traditional FBP/QDS+ in 320-slice CT coronary angiography at standard radiation doses.
منابع مشابه
Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...
متن کاملEvaluation of heavily calcified vessels with coronary CT angiography: comparison of iterative and filtered back projection image reconstruction.
PURPOSE To prospectively compare traditional filtered back projection (FBP) and iterative image reconstruction for the evaluation of heavily calcified arteries with coronary computed tomography (CT) angiography. MATERIALS AND METHODS The study had institutional review board approval and was HIPAA compliant. Written informed consent was obtained from all patients. Fifty-five consecutive patien...
متن کاملIterative reconstruction and individualized automatic tube current selection reduce radiation dose while maintaining image quality in 320-multidetector computed tomography coronary angiography☆
AIM To assess the effect of two iterative reconstruction algorithms (AIDR and AIDR3D) and individualized automatic tube current selection on radiation dose and image quality in computed tomography coronary angiography (CTCA). MATERIALS AND METHODS In a single-centre cohort study, 942 patients underwent electrocardiogram-gated CTCA using a 320-multidetector CT system. Images from group 1 (n = ...
متن کاملProspective evaluation of the influence of iterative reconstruction on the reproducibility of coronary calcium quantification in reduced radiation dose 320 detector row CT.
BACKGROUND Coronary artery calcium (CAC) predicts coronary heart disease events and is important for individualized cardiac risk assessment. This report assesses the interscan variability of CT for coronary calcium quantification using image acquisition with standard and reduced radiation dose protocols and whether the use of reduced radiation dose acquisition with iterative reconstruction (IR;...
متن کاملThe effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography.
OBJECTIVE To evaluate the effect of adaptive iterative dose reduction (AIDR) on image noise and image quality as compared with standard filtered back projection (FBP) in 320-detector row CT coronary angiography (CTCA). METHODS 50 patients (14 females, mean age 68 ± 9 years) who underwent CTCA (100 kV or 120 kV, 400-580 mA) within a single heartbeat were enrolled. Studies were reconstructed wi...