Sources of error in determining lead in blood by atomic absorption spectrophotometry.

نویسندگان

  • L E Kopito
  • M A Davis
  • H Shwachman
چکیده

203Pb was used to monitor sample-preparation techniques used in four atomic absorption methods for determination of lead in blood. Sources of error and their magnitude were identified and measured for each of the following analytical procedures: precipitation with trichloroacetic acid, separation with ammonium pyrrolidine dithiocarbonate into methyl isobutyl ketone, digestion with acids, and coprecipitation with bismuth and direct analysis after a “nonextraction” procedure. The determination of lead in blood supplemented with inorganic lead was compared with that of naturally bound lead obtained from experimentally poisoned animals. Because of differences in in vivo and in vitro lead binding, recovery of added inorganic lead may not accurately reflect the fate of endogenous lead in some analytical procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Direct determination of lead in blood by flameless atomic absorption spectrophotometry].

A simple and direct method for determining lead in blood by flameless atomic absorption spectrophotometry was developed by modifying the method of Hodges and Skelding (1983). In the present method, a graphite tube was coated with molybdenum and both Triton X-100 and phosphoric acid were added to heparinized whole blood. The calibration curve for lead determination, prepared by adding standard l...

متن کامل

Blood Lead Level in Opiate Addicts Hospitalized in the Intensive Care Unit of a Trauma Referral Center in Kerman, Iran

Background: Opium is the most commonly-used narcotic in Iran and some Asian countries. There are many reports of lead poisoning in opium users. Lead poisoning encompasses a wide range of symptoms the incidence and severity of which depend on the concentration and duration of contact with lead. The present study compares blood levels of lead in two groups of non...

متن کامل

Direct determination of lead and cadmium in blood and urine by flameless atomic absorption spectrophotometry.

We describe procedures for direct determination of lead and cadmium in blood and urine by flameless atomic absorption spectrophotometry. Before analysis, the samples are pre-ashed in microboats in an ordinary laboratory oven. In this way, many samples can be prepared and pre-ashed simultaneously. We find the procedures presented in this work to be rapid, accurate, and precise.

متن کامل

Micromethod for determining total iron-binding capacity by flameless atomic absorption spectrophotometry.

Because of the large quantities of venous blood required, assays of total iron-binding capacity (TIBC) and serum iron are often omitted in diagnostic tests involving small children. As an alternative to the conventional method of assessing TIBC, we developed a micromethod based on flameless atomic absorption spectrophotometry (flameless AAS). Additionally, the standard microproc#{233}dure for d...

متن کامل

Lead level in pregnant women suffering from pre-eclampsia in Dakahlia, Egypt.

BACKGROUND Lead toxicity is a prevalent health problem in both developed and developing countries. One of the proposed mechanisms for lead-induced organ damage is oxidative stress. Oxidative stress is well-associated with the pregnancy disorder, pre-eclampsia. Exposure to lead may be one of the sources of the oxidative stress that leads to development of pre-eclampsia in pregnant women. OBJEC...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 20 2  شماره 

صفحات  -

تاریخ انتشار 1974