Determination of Static Load Models from Ltc and Capacitor Switching Tests
نویسنده
چکیده
This article investigates the characteristics of a pure residential load through field tests. Staged voltage perturbations by station transformer tapchanging are induced both with and without switching ON the feeder shunt capacitors. Sudden voltage deviations by capacitor switching are attempted. Static load parameters are derived from the recorded load response to voltage variations. It is found that the load real and reactive powers can be respectively approximated by a linear and a quadratic function of voltage.
منابع مشابه
Transient Minimization Within Static Var Compensated Distribution Systems
VAR support should be supplied as close to the load as possible to minimize transmission losses. For voltage control and for improvement of total power factor in a distribution system the circuit- breaker switched capacitor banks can be used. The problems with this solution are the voltage steps caused by the large sizes of the capacitor banks as well as the transients caused on insertion. Thyr...
متن کاملAutomatic On-line Controller for Coordinated Slow Voltage Control
This paper proposes an automatic discrete slow voltage controller, which is motivated towards implementation in the western Oregon system in Pacific Northwest. This part of the system is far from generators and the main voltage control devices are capacitor banks, reactor banks and LTC transformers. The project pursues a model-based approach for selecting the discrete control actions for on-lin...
متن کاملImpacts of Voltage Control Methods on Distribution Circuit’s Photovoltaic (PV) Integration Limits
The widespread integration of photovoltaic (PV) units may result in a number of operational issues for the utility distribution system. The advances in smart-grid technologies with better communication and control capabilities may help to mitigate these challenges. The objective of this paper is to evaluate multiple voltage control methods and compare their effectiveness in mitigating the impac...
متن کاملIn situ determination of the static inductance and resistance of a plasma focus capacitor bank.
The static (unloaded) electrical parameters of a capacitor bank are of utmost importance for the purpose of modeling the system as a whole when the capacitor bank is discharged into its dynamic electromagnetic load. Using a physical short circuit across the electromagnetic load is usually technically difficult and is unnecessary. The discharge can be operated at the highest pressure permissible...
متن کاملA Hybrid Algorithm for Optimal Location and Sizing of Capacitors in the presence of Different Load Models in Distribution Network
In practical situations, distribution network loads are the mixtures of residential, industrial, and commercial types. This paper presents a hybrid optimization algorithm for the optimal placement of shunt capacitor banks in radial distribution networks in the presence of different voltage-dependent load models. The algorithm is based on the combination of Genetic Algorithm (GA) and Binary Part...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -