A Computer-Graphic Display for Real-Time Operator Feedback during Interventional X-Ray Procedures
نویسندگان
چکیده
The harmful effects of ionizing radiation, as employed in a variety of medical imaging procedures, have been well studied and documented. To minimize risk to patients, operators must continually assess the dose rate and cumulative dose to the patient at each area of exposure. We have developed a computer graphic dose management display system which provides this operator feedback. The system is comprised of a signal processing module which reads the state of a fluoroscopy machine, a transmission ionization chamber for exposure measurement, and a visualization of the patient that displays the current level of radiation intensity and accumulated dose at every location on the body. The system shows the beam projection and orientation of the machine and color-coded dose metrics on the patient graphic model in real time. Additionally, a database system has been incorporated to allow for recording and playback of the entire procedure.
منابع مشابه
Determining the Proper compression Algorithm for Biomedical Signals and Design of an Optimum Graphic System to Display Them (TECHNICAL NOTES)
In this paper the need for employing a data reduction algorithm in using digital graphic systems to display biomedical signals is firstly addressed and then, some such algorithms are compared from different points of view (such as complexity, real time feasibility, etc.). Subsequently, it is concluded that Turning Point algorithm can be a suitable one for real time implementation on a microproc...
متن کاملNew Approaches to Catheter Navigation for Interventional Radiology Simulation
For over 20 years, interventional methods have improved the outcomes of patients with cardiovascular disease. However, these procedures require an intricate combination of visual and tactile feedback and extensive training periods. In this paper, we describe a series of novel approaches that have lead to the development of a high-fidelity simulation system for interventional neuroradiology. In ...
متن کاملSimulation of Percutaneous Transhepatic Cholangiography Training Simulator with Real-time Breathing Motion
Purpose We present here a simulator for interventional radiology focusing on percutaneous transhepatic cholangiography (PTC). This procedure consists of inserting a needle into the biliary tree using fluoroscopy for guidance. Methods The requirements of the simulator have been driven by a task analysis. The three main components have been identified: the respiration, the real-time X-ray display...
متن کاملReal-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures.
OBJECTIVES The aim of this study was to accurately assess the radiation exposure received by patients during cardiac catheterization in a large sample representative of the current state of practice in cardiac angiography. BACKGROUND Radiation exposure to patients and laboratory staff has been recognized as a necessary hazard in coronary angiography. The effects on x-ray exposure of the incre...
متن کاملWireless Accelerometer for MRI-Guided Interventional Procedures
MRI-guidance is increasingly used for minimally-invasive procedures, such as biopsy, and requires real-time active tracking of surgical instruments. Although optical and MR-based fiducial tracking devices have been used, these systems rely on complex contact with the operator or line-of-sight access for effective operation. A more straight-forward and clinically robust method is required to all...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004