Comparison of Thyroid Blood Flow and Uptake Indices Using Technetium-99m Pertechnetate in Patients with Graves’ Disease and Euthyroid Subjects

نویسندگان

  • Hamid Javadi
  • Ali Mahmoud Pashazadeh
  • Mehdi Mogharrabi
  • Iraj Nabipour
  • Mohammadreza Kalantarhormozi
  • Majid Assadi
چکیده

OBJECTIVE The aim of the present study was to evaluate parameters of early blood flow (EBF) including duration of EBF, perfusion index (PI), uptake indexes 1 and 2 (UI1 and UI2) derived from dynamic thyroid scintigraphy in patients with Graves' disease (GD), and euthyroid (EI). Maximum instant uptake and maximum uptake of the thyroid gland were also assessed. METHODS A total of 50 patients with GD and EI were included in this study. Each patient underwent two dynamic scans of 1-minute (20 images at 3 seconds) and 20-minute (20 images at 1 minute) with 99mTcO4. The time-activity curve of a 1-minute scan was employed to derive EBF parameters; likewise, the time-activity curve of a 20-minute scan was used to determine maximum instant uptake, and the gradient of the curve from the 10th to 20th minute was used to assess maximum uptake. RESULTS Values of EBF duration, PI, UI1, UI2, and maximum instant uptake were significantly lower in patients with GD than in those with EI (p<0.05). The calculated gradient of the second half of the curves for all of the patients ranged from 0 to 0.88 and was significantly higher in patients with GD than in those with EI. CONCLUSION Lower values of PI, UI1, UI2 and durations of EBF, along with faster maximum instant uptake in patients with GD in comparison to EI are indicators of a heightened desire for hyper-functioning thyroid glands of patients with GD to absorb 99mTcO4. Additionally, because of the uprising gradient at the end of the 20-minute time-activity curve, a maximum thyroid uptake of 99mTcO4 was achieved at more than 20 minutes after the radiopharmaceutical injection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cut off value of technetium uptake in the differential diagnosis of Graves, disease and subacute thyroiditis

Objective(s):The aim of this study was to determine whether technetium (99mTc) uptake is a relevant method for the differential diagnosis of Graves disease and subacute thyroiditis and calculate its cutoff value in case of its relevancy. Methods: A total of 69 patients, who were followed up (>3 months) in our hospital for thyrotoxi...

متن کامل

Quantitative single-photon emission computed tomography/computed tomography for technetium pertechnetate thyroid uptake measurement

OBJECTIVES Technetium pertechnetate (TcO4) is a radioactive tracer used to assess thyroid function by thyroid uptake system (TUS). However, the TUS often fails to deliver accurate measurements of the percent of thyroid uptake (%thyroid uptake) of TcO4. Here, we investigated the usefulness of quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) after injection o...

متن کامل

Thyroid blood flow and uptake of technetium-99m pertechnetate in Graves' disease.

The aim of this study was to assess the relation of early thyroid blood flow (EBF) and technetium-99m pertechnetate ((99m)TcO(-)(4)) uptake, as an early diagnostic index in patients with Graves' disease (GD) by dynamic thyroid scintigraphy (40 frames, 3 sec/frame). Thirty patients with GD with mean age 50.0 +/- 9.0 y, range: 35.0-69.0 y, were studied. The results obtained were compared with tho...

متن کامل

Analysis of the factors associated with Tc-99m pertechnetate uptake in thyrotoxicosis and graves' disease.

To determine the factors associated with 20 minute Tc-99m pertechnetate thyroid uptake, we examined all patients in whom thyrotoxicosis was diagnosed at Chiba-Hokusoh Hospital, Nippon Medical School from 2001 April through 2003 March. Patients with thyrotoxicosis diagnosed during this period were 57 with Graves' disease (76%), 11 with transient hyperthyroxinemia (TH)(14.7%), and 7 with subacute...

متن کامل

Inaccuracy of Thyroid to Background Uptake Ratio in Evaluating Technetium-99m-pertechnetate Thyroid Uptake and Establishing an Improved Algorithm

Objective(s): The aim of this study was to explore the accuracy of thyroid to background uptake ratio (UR) in the evaluation of 99mTc-pertechnetate thyroid uptake (TcTU) and establishment of an improved algorithm. Methods: This study was conducted on the thyroid images of 322 patients with thyroid diseases and 67 controls. For the purpos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2014