Ureteral fistula is a serious complication of abdomino-pelvic surgeries, often resulting in poor outcomes owing to lack of proper treatment. We report the case of a 49-year-old woman who underwent placement of a silicone-covered ureteral occlusion stent in her right ureter for the management of ureteral leakage after pelvic surgery. A ureterogram obtained 18 months following the stent placement confirmed that there was no stent migration or additional urine leakage. We propose that the silicone-covered ureteral occlusion stent is practical, fast, and safe for the management of ureteral leakage.
منابع مشابه
Self-expanding metallic ureteral stents for treatment of ureteral stenosis after kidney transplantation.
The incidence of post-renal transplantation ureteral stenosis ranges from 2%-12%. Because the role of self-expanding ureteral metallic stents for its treatment has been scarcely reported, the aim of this study was to evaluate the efficacy of Nitinol stents. Eleven ureteral stenoses in patients with chronic graft dysfunction (8 cases) or high surgical risk (3 cases) were treated by antegrade per...
متن کاملEndoscopic ultrasound-guided gallbladder drainage for acute cholecystitis with a silicone-covered nitinol short bilaterally flared stent: a case series
[This corrects the article DOI: 10.1055/s-0043-118659.].
متن کاملA Novel Type of Ureteral Stents in the Treatment of a Bilateral Iatrogenic Transaction of the Ureters
This report illustrates the case of a patient who suffered an iatrogenic complete injury of both ureters after a complex surgical procedure to remove a large sacral chordoma. Ureteral recanalization was achieved with two removable, autoexpandable, and polytetrafluoroethylene covered nitinol stents. To our knowledge, we describe the first application of this type of stents to treat a bilateral u...
متن کاملCombination of the "bear claw" (over-the-scope-clip system) and fully covered stent for the treatment of post-operative anastomotic leak.
The “bear claw” or over-the-scope clip (OTSC) system (Ovesco Endoscopy, Tübingen, Germany) is an innovative clipping device made of superelastic biocompatible nitinol [1–3]. This clipping device was developed to close wall defects of the luminal gastrointestinal tract, such as perforations, anastomotic leaks, fistulas, and large defects occurring after endoscopic full-thickness resection [1]. T...
متن کاملTreatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent
OBJECTIVE We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. MATERIALS AND METHODS Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 19 شماره
صفحات -
تاریخ انتشار 2015