Facts and myths about electrical measurement of stratum corneum hydration state.

نویسندگان

  • O G Martinsen
  • S Grimnes
چکیده

Some of the views presented in the chapter on 'Examination of stratum corneum hydration state by electrical methods' in Skin Bioengineering - Techniques and Applications in Dermatology and Cosmetology (Karger, 1998) are in strong disagreement with the results from basic research that has been conducted on skin impedance measurement over the last decades. This research has e.g. non-ambiguously shown that the frequency response of the stratum corneum does not obey the Cole equation and that measurement depth is strongly dependent on measurement frequency. One consequence of these findings is that multifrequency electrical measurements on stratum corneum are impossible to achieve in vivo with any electrode system known today. Hence, electrical measurements of stratum corneum hydration must be conducted at one single, low frequency.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Environmental Factors (rh, T) and the Stratum Corneum Barrier Function to Occupational Chemicals

Skin permeation for the occupational chemicals mainly depends on the Stratum Corneum (SC), which behaves as a barrier against the entrance of any substance applied on it. The hydration state of the SC plays a crucial role for its barrier function and the permeation process, especially for the water-soluble substances. In this work the relationship of the environmental Relative Humidity (RH) and...

متن کامل

بی‌خطری دو فرآورده‌ی مرطوب‌کننده: کارآزمایی بالینی دارای گروه شاهد فاز I

Background and Aim: Moisturizers have important roles in the treatment of dry skin. Their safety has to be evaluated on human volunteers in order to assess their potential skin irritation. Measurements of skin biophysical parameters can be used as fast and noninvasive methods to assess any harmful effect of cosmetic formulations on the skin sites where those products are applied. Methods: Tw...

متن کامل

Opto-thermal technique for in-vivo stratum corneum hydration measurement

A new method for measuring stratum corneum hydration in-vivo, using opto-thermal transient emission radiometry with 2.94pm Er:YAG excitation and wavelength selective detection, is described. Results on skin recovery following exogenous hydration, skin stripping with Sellotape and wound healing are presented.

متن کامل

Gravimetric Method for in Vitro Calibration of Skin Hydration Measurements

A novel method for in vitro calibration of skin hydration measurements is presented. The method combines gravimetric and electrical measurements and reveals an exponential dependency of measured electrical susceptance to absolute water content in the epidermal stratum corneum. The results also show that absorption of water into the stratum corneum exhibits three different phases with significan...

متن کامل

Characterization of Stratum Corneum Molecular Dynamics by Natural-Abundance 13C Solid-State NMR

Despite the enormous potential for pharmaceutical applications, there is still a lack of understanding of the molecular details that can contribute to increased permeability of the stratum corneum (SC). To investigate the influence of hydration and heating on the SC, we record the natural-abundance (13)C signal of SC using polarization transfer solid-state NMR methods. Resonance lines from all ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Dermatology

دوره 202 2  شماره 

صفحات  -

تاریخ انتشار 2001