Determination of urea in serum by using naturally immobilized urease in a flow injection conductimetric system.

نویسندگان

  • L C de Faria
  • C Pasquini
  • G de Oliveira Neto
چکیده

A flow injection method was developed, aimed at the determination of urea in human serum. The system makes use of the naturally immobilized urease present in Canavalia ensiformis DC (jack bean). A column is filled with small pieces of this bean, and the sample (50 microliters) containing urea passes through it carried by a 1% NaCl solution. On leaving the column the stream is merged with an alkaline reagent (0.5 mol dm-3 NaOH; 0.5% disodium dihydrogen ethylenediaminetetraacetate). The ammonium ions, arising from the enzymatic reaction that occurs inside the column, are changed into the molecular form, which permeates a polytetrafluoroethylene membrane and is received in a de-ionized water acceptor stream. The ammonia ionizes causing an increase in the conductance, which is proportional to the urea content of the sample. About 40 samples can be processed in 1 h with negligible carry-over and with a relative standard deviation of 1% or less. The results are in agreement with those obtained by a standard spectrophotometric method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of urea in serum based on the combination of an enzymatic reaction with immobilized urease and ion chromatographic analysis.

A quantitative method for the determination of urea in serum was studied. An ion chromatograph (IC) with a conductivity detector was used in this method, where the chromatograph was modified by placing an immobilized urease column between the injection loop and a guard column of the cation analysis column. Immobilized urease was prepared by the adsorption of urease on cedar sawdust with triethy...

متن کامل

Rapid-flow enthalpimetric determination of urea in serum, with use of an immobilized urease reactor.

We used a differential thermal detector in conjunction with an immobilized urease reactor to determine urea in serum. Samples (120 mul) are introduced into a flow stream and passed through an "adiabatic" column, which is packed with enough insolubilized urease to completely convert urea to ammonia and carbon dioxide. Measured temperature changes are directly proportional to the serum urea conce...

متن کامل

Flow Injection System with Potentiometric Detection for the Determination of Urea Content in Milks

Two variant manifolds of a flow injection analysis (FIA) system are described for the determination of urea content in milks. This determination consists of the enzymatic reaction of urea with urease in which ammonium ion is formed. Ammonium is converted to ammonia by adding a NaOH solution and then led to a gas diffusion unit in which it diffuses to an acceptor channel (Tris/HCl, pH 7.5). Here...

متن کامل

Immobilized-enzyme nylon-tube reactors for routine determination of urea and citrulline in serum.

A continuous-flow clinical analyzer for the routine estimation of urea is described that makes use of an immobilized-enzyme nylon-tube reactor as part of a flow-through system (a Technicon AutoAnalyzer I). Results of blood-urea analyses by use of the immobilized urease are compared with determinations made with the diacetyl monoxime method and the urease solution method. Clinical trials carried...

متن کامل

A Conductometric Urea Biosensor by Direct Immobilization of Urease on Pt Electrode

Urease was immobilized on platinum electrode both by chemical binding and electropolymerization.The conductometric urea biosensor thus prepared showed a detection limit of 4.9×10-5 M and linear dynamic range from 4.9×10-5 to 5.8×10-3 M for urea concentration when the enzyme is covalently immobilized on Pt electrodes. Conductometric transducers respo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 116 4  شماره 

صفحات  -

تاریخ انتشار 1991