Instrumentation is described that has been constructed at the National Institute of Standards and Technology (NIST) for the measurement of regular re ̄ectance and transmittance over the 2±25 mm wavelength region. This includes both specialized accessories used with Fourier-transform infrared (FT-IR) spectrometers and laser-based systems for high optical density transmittance measurements. The FT-IR systems have been used to develop standard reference materials for IR regular transmittance. # 1999 Published by Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Infrared diffuse re ̄ectance instrumentation and standards at NIST

A spectrophotometer system for spectral characterization of materials in the infrared has been built around a bench-top Fourier transform instrument. Its capabilities include the measurement of directional-hemispherical re ̄ectance from 1 to 18 mm. The spectral re ̄ectance measurement is performed with an integrating sphere with an incidence angle of 88. Both relative and absolute measurements ca...

متن کامل

Comparison of near-infrared transmittance and reflectance measurements using dispersive and Fourier transform spectrophotometers

A spectrophotometer based on an integrating sphere coupled to a commercial Fourier Transform Infrared (FTIR) instrument has been constructed for regular spectral transmittance and re ectance measurements over the 1 m m to 18 m m wavelength region. Despite the large number of sources of error that often limit the radiometric accuracy of FTIR measurements, we demonstrate uncertainties similar to...

متن کامل

An investigation of remotely-sensed soil depth in the optical region

The remotely-sensed soil depth in the visible and near-infrared (near-IR) spectral region is investigated by using a numerical radiative transfer model of the coupled atmosphere and soil media. The sensible depth is determined by examining the downward hemispheric transmittance pro® le, hemispherical re ̄ ectance, and bidirectional re ̄ ectance with diVerent solar zenith angles at diVerent wavele...

متن کامل

Challenges in Providing Standard Reference Materials

The NIST Analytical Chemistry Division has supplied transmittance verification and wavelength calibration standard reference materials (SRMs) specialized to the needs of chemical and pharmaceutical spectrophotometric analysis since 1970. Growing demand for UV/visible standards stems from the increasingly routine use of spectrophotometers for pharmaceutical quality control and from the escalatio...

متن کامل

The NIST Quantitative Infrared Database

National Institute of Standards and Technology, Gaithersburg, MD 20899-0001 With the recent developments in Fourier transform infrared (FTIR) spectrometers it is becoming more feasible to place these instruments in field environments. As a result, there has been enormous increase in the use of FTIR techniques for a variety of qualitative and quantitative chemical measurements. These methods off...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999