The effect of Gonioscopy on keratometry and corneal surface topography

نویسندگان

  • Mathew K George
  • Thomas Kuriakose
  • Brian M DeBroff
  • John W Emerson
چکیده

BACKGROUND Biometric procedures such as keratometry performed shortly after contact procedures like gonioscopy and applanation tonometry could affect the validity of the measurement. This study was conducted to understand the short-term effect of gonioscopy on corneal curvature measurements and surface topography based Simulated Keratometry and whether this would alter the power of an intraocular lens implant calculated using post-gonioscopy measurements. We further compared the effect of the 2-mirror (Goldmann) and the 4-mirror (Sussman) Gonioscopes. METHODS A prospective clinic-based self-controlled comparative study. 198 eyes of 99 patients, above 50 years of age, were studied. Exclusion criteria included documented dry eye, history of ocular surgery or trauma, diabetes mellitus and connective tissue disorders. Auto-Keratometry and corneal topography measurements were obtained at baseline and at three follow-up times - within the first 5 minutes, between the 10th-15th minute and between the 20th-25th minute after intervention. One eye was randomized for intervention with the 2-mirror gonioscope and the other underwent the 4-mirror after baseline measurements. t-tests were used to examine differences between interventions and between the measurement methods. The sample size was calculated using an estimate of clinically significant lens implant power changes based on the SRK-II formula. RESULTS Clinically and statistically significant steepening was observed in the first 5 minutes and in the 10-15 minute interval using topography-based Sim K. These changes were not present with the Auto-Keratometer measurements. Although changes from baseline were noted between 20 and 25 minutes topographically, these were not clinically or statistically significant. There was no significant difference between the two types of gonioscopes. There was greater variability in the changes from baseline using the topography-based Sim K readings. CONCLUSION Reversible steepening of the central corneal surface is produced by the act of gonioscopy as measured by Sim K, whereas no significant differences were present with Auto-K measurements. The type of Gonioscope used does not appear to influence these results. If topographically derived Sim K is used to calculate the power of the intraocular lens implant, we recommend waiting a minimum of 20 minutes before measuring the corneal curvature after gonioscopy with either Goldmann or Sussman contact lenses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Effect of disagreement between refractive, keratometric, and topographic determination of astigmatic axis on suture removal after penetrating keratoplasty.

BACKGROUND/AIMS Post-keratoplasty astigmatism can be managed by selective suture removal in the steep axis. Corneal topography, keratometry, and refraction are used to determine the steep axis for suture removal. However, often there is a disagreement between the topographically determined steep axis and sutures to be removed and that determined by keratometry and refraction. The purpose of thi...

متن کامل

Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system.

AIMS To map the thickness, elevation (anterior and posterior corneal surface), and axial curvature of the cornea in normal eyes with the Orbscan corneal topography system. METHODS 94 eyes of 51 normal subjects were investigated using the Orbscan corneal topography system. The anterior and posterior corneal elevation maps were classified into regular ridge, irregular ridge, incomplete ridge, i...

متن کامل

بررسی اثر قطره هوماتروپین 2% بر روی توپوگرافی قرنیه

 ABSTRACT The purpose of this study was the evaluation of cycloplegic effect of homatropine 2% on central corneal curvature and power. 43 volunteers who participated in the study were examined. Thirty-nine of them (28 men and 11 women) which had normal eyes with visual acuity of 20/20 and a mean age of 29.6 ± 6.7 years were selected. Then corneal topography was performed on both eyes. After per...

متن کامل

Comparison of Placido disc and Scheimpflug image-derived topography-guided excimer laser surface normalization combined with higher fluence CXL: the Athens Protocol, in progressive keratoconus

BACKGROUND The purpose of this study was to compare the safety and efficacy of two alternative corneal topography data sources used in topography-guided excimer laser normalization, combined with corneal collagen cross-linking in the management of keratoconus using the Athens protocol, ie, a Placido disc imaging device and a Scheimpflug imaging device. METHODS A total of 181 consecutive patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BMC Ophthalmology

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2006