Diaphragm assessment by two dimensional speckle tracking imaging in normal subjects

نویسندگان

  • Sam R. Orde
  • Andrea J. Boon
  • Daniel G. Firth
  • Hector R. Villarraga
  • Hiroshi Sekiguchi
چکیده

BACKGROUND Conventionally, ultrasonographic assessment of diaphragm contractility has involved measuring respiratory changes in diaphragm thickness (thickening fraction) using B-mode or caudal displacement with M-mode. Two-dimensional speckle-tracking has been increasingly used to assess muscle deformation ('strain') in echocardiography. We sought to determine in a pilot study if this technology could be utilized to analyze diaphragmatic contraction. METHODS Fifty healthy adult volunteers with normal exercise capacity underwent ultrasound imaging. A linear array transducer was used for the assessment of diaphragm thickness, thickening fraction (TF), and strain in the right anterior axillary line at approximately the ninth intercostal space. A phased array transducer was applied subcostally for the assessment of diaphragm displacement on the right mid-clavicular line. Diaphragmatic images were recorded from the end of expiration through the end of inspiration at 60 % maximal inspiratory capacity. Diaphragm strain was analyzed off-line by speckle tracking imaging. Blinded inter- and intra-rater variability was tested in 10 cases. RESULTS Mean right diaphragm thickness at end-expiration (±SD: standard deviation) was 0.24 cm (±0.1), with TF of 45.1 % (±12) at 60 % peak inspiratory effort. Mean right diaphragm caudal displacement was 4.9 cm (±1). Mean right diaphragm strain was -40.3 % (±9). A moderate correlation was seen between longitudinal strain and TF (R(2) 0.44, p < 0.0001). A weak correlation was seen between strain and caudal displacement (R(2) 0.14, p < 0.01), and an even weaker correlation was seen between caudal displacement and TF (R(2) 0.1, p = 0.04). Age, gender, and body mass index were not significantly associated with right diaphragm strain or TF. Although inter- and intra-rater variability was overall good for TF, caudal displacement, and strain (inter-rater R(2); 0.8, 0.9, and 0.7, respectively [p < 0.01], intra-rater R(2); 0.9, 0.7, and 0.9, respectively [p < 0.01]), strain values did have a slightly lower inter-rater repeatability. CONCLUSIONS Diaphragmatic strain estimated by speckle tracking imaging was associated with conventional ultrasound measures of diaphragmatic function (TF and caudal displacement). Further clinical studies are warranted to investigate its clinical utility.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Two-dimensional strain ultrasound speckle tracking as a novel approach for the evaluation of right hemidiaphragmatic longitudinal deformation

The diaphragm is an important respiratory organ. The aim of this study was to quantitatively evaluate the longitudinal deformation of the right hemidiaphragm in normal subjects using two-dimensional strain ultrasound speckle tracking. Twenty-one healthy subjects were enrolled in this study. GE Healthcare Vivid E9 equipment with M5S probe and Q-analysis software were used. Negative strain values...

متن کامل

Temperature Mapping Using Ultrasound Digital Images

Introduction:  The  success  of  hyperthermia  depends  on  the  accuracy  of  the  temperature  monitoring in the tumor and the surrounding normal tissue. In this study, the temperature changes  were determined by computing the speckle displacement in the ultrasound digital images. Speckle  tracking algorithm was used to compute the displacement.  Materials and Methods: The experiment was perf...

متن کامل

Assessment of the Rotation Motion at the Papillary Muscle Short-Axis Plane with Normal Subjects by Two-Dimensional Speckle Tracking Imaging: A Basic Clinical Study

BACKGROUND The aim of this study was to observe the rotation patterns at the papillary muscle plane in the Left Ventricle(LV) with normal subjects using two-dimensional speckle tracking imaging(2D-STI). METHODS We acquired standard of the basal, the papillary muscle and the apical short-axis images of the LV in 64 subjects to estimate the LV rotation motion by 2D-STI. The rotational degrees a...

متن کامل

Feasibility and reference values of left atrial longitudinal strain imaging by two-dimensional speckle tracking

BACKGROUND The role of speckle tracking in the assessment of left atrial (LA) deformation dynamics is not established. We sought to determine the feasibility and reference ranges of LA longitudinal strain indices measured by speckle tracking in a population of normal subjects. METHODS In 60 healthy individuals, peak atrial longitudinal strain (PALS) and time to peak longitudinal strain (TPLS)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015