Sequence of mitral valve motion and transmitral blood flow during manual cardiopulmonary resuscitation in dogs.

نویسندگان

  • M P Feneley
  • G W Maier
  • J W Gaynor
  • S A Gall
  • J A Kisslo
  • J W Davis
  • J S Rankin
چکیده

According to the thoracic pump model of cardiopulmonary resuscitation (CPR), the heart serves as a passive conduit for blood flow from the pulmonary to the systemic vasculature, necessitating an open mitral valve and anterograde transmitral blood flow during chest compression. To assess the applicability of this model to manual CPR techniques, two-dimensional echocardiograms were recorded from the right chest wall and/or the esophagus in nine dogs (18 to 26 kg) during manual CPR. The aortic valve opened with chest compression and closed with release, while the pulmonary and tricuspid valve leaflets closed with compression and opened during release. The mitral valve remained open during ventilation alone and during abdominal compressions. With the onset of brief, high-velocity (high-impulse) chest compressions, the mitral valve closed rapidly and the left ventricle was deformed, whether compressions were applied to the sternum or the left mid-chest wall. The mitral valve reopened with release of each compression. Left atrial echocardiographic contrast injections confirmed the absence of anterograde transmitral blood flow during high-impulse compression and its presence during release. Failure of mitral leaflet approximation during chest compression was observed only when a very low-velocity, prolonged (low-impulse) compression technique was used, or when regions that did not directly overlie the heart were compressed. Consistent with these observations, simultaneous recordings of the left ventricular and left atrial pressures during high-impulse sternal compressions in five dogs (19 to 25 kg) demonstrated peak and mean left ventriculoatrial pressure gradients of 38.5 +/- 4.0 and 13.5 +/- 2.9 mm Hg, respectively, and these pressure gradients declined with less impulsive compressions. The observations made during all but low-impulse chest compressions are inconsistent with the thoracic pump model, and support direct cardiac compression as the primary mechanism of forward blood flow with more impulsive manual chest compression techniques.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

LABORATORY INVESTIGATION PHYSIOLOGY Sequence of mitral valve motion and transmitral blood flow during manual cardiopulmonary resuscitation in dogs

According to the thoracic pump model of cardiopulmonary resuscitation (CPR), the heart serves as a passive conduit for blood flow from the pulmonary to the systemic vasculature, necessitating an open mitral valve and anterograde transmitral blood flow during chest compression. To assess the applicability of this model to manual CPR techniques, two-dimensional echocardiograms were recorded from ...

متن کامل

Evaluation of diastolic blood flow dynamic of the left ventricle in dogs with mitral valve regurgitation using vector flow mapping

Mitral valve regurgitation (MVR) is a common valvular disease in dogs. Hydrokinetic evaluation of the blood flow within the ventricles has become possible by vector flow mapping (VFM), which shows the blood flow within the ventricles in vector and vortex flows. Blood flow within the left ventricle of MVR dogs was compared at different stages of MVR and to that of normal dogs. 14 normal dogs and...

متن کامل

Cyclic elevation of intrathoracic pressure can close the mitral valve during cardiac arrest in dogs.

Mitral valve closure during cardiopulmonary resuscitation may result from direct cardiac compression. An alternative hypothesis is that with a rise in intrathoracic pressure, mitral valve closure can occur but may be influenced by whether the lungs are inflated or deflated. To test this hypothesis, we placed a large-bore cannula into the thoraces of 11 dogs. Intrathoracic pressure was changed b...

متن کامل

Visualization of cardiac valve motion in man during external chest compression using two-dimensional echocardiography. Implications regarding the mechanism of blood flow.

Five patients who underwent cardiopulmonary resuscitation (CPR) were studied by two-dimensional echocardiography to assess valve motion. The mitral valve remained open throughout the entire compression-release cycle of CPR. The aortic valve opened during the compression phase of CPR and closed during the release phase. The pulmonic valve moved toward the closed position during the compression p...

متن کامل

Physiology of blood flow during cardiopulmonary resuscitation. A transesophageal echocardiographic study.

BACKGROUND There are two competing theories of the mechanism of blood flow during cardiopulmonary resuscitation. The "cardiac pump" theory postulates that blood flows because the heart is squeezed between the sternum and the spine. The "thoracic pump" theory postulates that blood flows from the thorax because intrathoracic pressure exceeds extrathoracic vascular pressure and that flow is restri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 76 2  شماره 

صفحات  -

تاریخ انتشار 1987