Myocardial perfusion imaging based on the blood oxygen level-dependent effect using T2-prepared steady-state free-precession magnetic resonance imaging.

نویسندگان

  • David S Fieno
  • Steven M Shea
  • Yongzhong Li
  • Kathleen R Harris
  • J Paul Finn
  • Debiao Li
چکیده

BACKGROUND The decision to perform coronary revascularization procedures may hinge on assessment of myocardial perfusion reserve. Blood oxygen level-dependent (BOLD) MRI is a potential method to detect the effects of regional variations in myocardial blood flow during vasodilation. METHODS AND RESULTS We imaged dogs (n=13) on a 1.5-T whole-body MRI scanner using a new T(2)-prepared steady-state free-precession (SSFP) MRI pulse sequence sensitive to BOLD contrast. Images (in-plane resolution approximately 1 mm(2)) of 5 short-axis and 2 long-axis slices of the heart were acquired during graded levels of adenosine infusion via a surgically placed left circumflex (LCx) catheter (n=11) or via a right atrial catheter in animals with an LCx occluder (n=2). Relative myocardial perfusion was measured with the use of fluorescent microspheres. Signal intensity changes in myocardium subtended by the left anterior descending coronary artery were compared with those in the LCx region. Unprocessed T(2)-weighted images revealed changes in signal intensity corresponding to areas of regional vasodilation or reduced myocardial perfusion reserve during systemic vasodilation. At maximal vasodilation, the signal intensity ratio in the LCx versus left anterior descending territories increased by 33+/-4% compared with baseline, corresponding to a 3.8+/-0.3-fold increase in relative perfusion (P<0.01). MR intensity at progressive levels of vasodilation demonstrated good agreement with microsphere flow (R=0.80, P<0.01). CONCLUSIONS T(2)-prepared SSFP BOLD imaging is a promising method to determine an index of myocardial perfusion reserve in this animal model.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

T2-prepared steady-state free-precession for detection of hemodynamic significance of coronary artery stenosis - a comparison to fractional flow reserve

Background BOLD CMR has been shown to be able to detect myocardial perfusion differences. However, validation of BOLD CMR against FFR is lacking. Aim of our study was to analyze the potential diagnostic accuracy of blood oxygen level-dependent (BOLD) cardiac magnetic resonance imaging (CMR) in comparison to invasively measured fractional flow reserve (FFR) which served as gold standard for a he...

متن کامل

Assessment of segmental myocardial blood flow and myocardial perfusion reserve by adenosine-stress myocardial arterial spin labeling perfusion imaging.

PURPOSE To determine the feasibility of measuring increases in myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) on a per-segment basis using arterial spin labeled (ASL) magnetic resonance imaging (MRI) with adenosine vasodilator stress in normal human myocardium. MATERIALS AND METHODS Myocardial ASL scans at rest and during adenosine infusion were incorporated into a routine...

متن کامل

Myocardial Blood-Oxygen-Level-Dependent Magnetic Resonance Imaging with Balanced Steady-State Free Precession Imaging Approaches

The current state of myocardial Blood-Oxygen-Level-Dependent (BOLD) MRI with balanced steady-state free precession (SSFP) approaches is reviewed. Initial studies forming the basis for SSFP-based detection of oxygenation changes beginning with whole blood studies, progressing through controlled studies that consider microcirculatory changes in oxygenation in skeletal muscle and kidney, culminati...

متن کامل

Magnetic resonance imaging delineates the ischemic area at risk and myocardial salvage in patients with acute myocardial infarction.

BACKGROUND The area at risk (AAR) is a key determinant of myocardial infarction (MI) size. We investigated whether magnetic resonance imaging (MRI) measurement of AAR would be correlated with an angiographic AAR risk score in patients with acute MI. METHODS AND RESULTS Bright-blood, T2-prepared, steady-state, free-precession MRI was used to depict the AAR in 50 consecutive acute MI patients, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 110 10  شماره 

صفحات  -

تاریخ انتشار 2004