Hydrogen content in doped and undoped BaPrO3 and BaCeO3 by cold neutron prompt-gamma activation analysis

نویسندگان

  • Camille Y. Jones
  • Jian Wu
  • LiPing Li
  • Sossina M. Haile
چکیده

Proton uptake in undoped and Y-doped BaPrO3 has been measured by cold neutron prompt-gamma activation analysis, and compared to the proton uptake in Gd-doped BaCeO3, as determined by the same technique. The conventional proton incorporation model of perovskites in which oxygen ion vacancies, generated by the introduction of the trivalent dopant onto the tetravalent perovskite site, are filled with hydroxyl groups upon exposure of the sample to H2O containing atmospheres, predicts that the proton concentration in such materials should be no greater than the dopant concentration. In contradiction to this model, the proton concentration in BaPr1−xYxO3 after humidification is as much as three times greater than the dopant concentration, and even undoped samples contain a high concentration of protons. Moreover, x-ray photoemission spectra suggest that the Pr oxidation state is lowered upon hydration. In contrast, BaCe0.9Y0.1O3 shows a typical hydrogen concentration, of close to 90% of the yttrium concentration. The results are interpreted in terms of the variable valence of Pr, which can become reduced from the 4+ to the 3+ oxidation state upon exposure to water, and effectively behaves as a self-dopant within the structure. © 2005 American Institute of Physics. fDOI: 10.1063/1.1922590g

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shielding studies on a total-body neutron activation facility

Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...

متن کامل

Characterization of Am-Be neutron source based PGNAA setup using aqueous solutions of Chlorine and Boron

Background: A 5 Ci 241Am-Be radio isotopic neutron source-based prompt gamma neutron activation analysis (PGNAA) setup was designed for estimation of minimum detectable concentration (MDC) of elements in aqueous solutions. Materials and Methods: Performance variables related to PGNAA setup (source to sample distance, sample to detector distance and volume of water) were optimized experimentally...

متن کامل

Prompt Gamma-ray Activation Analysis for Certification of Sulfur in Fuel Oil SRMs.

A combination of cold neutron prompt gamma-ray activation analysis (CNPGAA) and thermal neutron (TN) PGAA was used to determine sulfur in fuel oils to develop a method to provide values for certification. CNPGAA was used to measure S/H mass ratios, and TNPGAA to measure hydrogen mass fractions. Measurements were combined to determine sulfur mass fractions (with expanded uncertainties) of 2.159 ...

متن کامل

Prompt-Gamma Activation Analysis

A permanent, full-time instrument for prompt-gamma activation analysis is nearing completion as part of the Cold Neutron Research Facility (CNRF). The design of the analytical system has been optimized for high gamma detection efficiency and low background, particularly for hydrogen. Because of the purity of the neutron beam, shielding requirements are modest and the scatter-capture background ...

متن کامل

Rapid communication Partial and total thermal neutron capture cross sections for non-destructive assay and transmutation monitoring

Accurate partial gamma-ray production cross sections were determined for the prompt and radioactive product decay gamma rays following cold neutron capture in Tc. They can be used for non-destructive assay of technetium by prompt gamma activation analysis (PGAA) and neutron activation analysis (NAA), offering orders of magnitude higher analytical sensitivities than passive gamma-ray counting. A...