The adsorption of major tear film lipids in vitro to various silicone hydrogels over time.
نویسندگان
چکیده
PURPOSE An in vitro study was conducted to measure the adsorption of major tear film lipids to soft contact lenses over time. METHODS Commercial balafilcon A (PureVision; Bausch & Lomb, Rochester, NY), galyfilcon A (Acuvue Advance; Johnson & Johnson Vision Care), lotrafilcon A and B (Night & Day And O(2)Optix; CIBA Vision, Duluth, GA), senofilcon A (Acuvue Oasys; Johnson & Johnson Vision Care, Jacksonville, FL) and etafilcon A (Acuvue 2; Johnson & Johnson Vision Care) lenses were all soaked for 14 hours in the dark at 34.5 degrees C in either cholesterol (CH; nonpolar lipid) or phosphatidylethanolamine (PE; polar lipid), tagged with 7-nitrobenz-2-oxa-1,3-diazol-4-yl (NBD) and N-fluorescein-5-thiocarbamoyl (FITC) labels, respectively. After rinsing, the lenses were measured for fluorescence and the corresponding lipid concentration was calculated from an appropriate standard curve. The lenses were then placed into a fresh 1-mL aliquot of the lipid being tested, and the procedure was repeated for 20 days. RESULTS In vitro adsorption of CH was greater that that of PE for all lens types (P < 0.0001 at days 14 and 20). After 20 days of soaking in PE, the lotrafilcon polymers showed the lowest adsorption of all the silicone hydrogel lenses tested at 0.4 and 1.5 microg/lens, for lotrafilcon A (P < or = 0.0001) and lotrafilcon B, respectively (P < or = 0.0001). Galyfilcon A and senofilcon A showed significantly higher PE adsorption at 5.1 and 4.9 microg/lens, respectively, compared with all other silicone hydrogel lenses investigated (P < 0.03). Senofilcon A (P < 0.0001) and balafilcon A (P < 0.02) had the highest affinity for CH of all the lens types after 20 days, with adsorptions of 23.2 and 24.1 microg/lens, respectively. Lotrafilcon B (P < 0.0001) showed the lowest in vitro adsorption of CH of all the lens types, at 3 mug/lens. CONCLUSIONS In vitro lipid adsorption varied greatly depending on the lens material for both polar and nonpolar lipids. Overall, there was less in vitro adsorption of lipid to the lotrafilcon A and B polymers than for any of the other silicone hydrogel polymers tested. The quantity of lipid adsorption by lotrafilcon polymers was similar to "conventional" hydrogel lenses.
منابع مشابه
Influence of lipid coatings on surface wettability characteristics of silicone hydrogels.
Insoluble lipids serve vital functions in our bodies and interact with biomedical devices, e.g., the tear film on a contact lens. Over a period of time, these naturally occurring lipids form interfacial coatings that modify the wettability characteristics of these foreign synthetic surfaces. In this study, we examine the deposition and consequences of tear film lipids on silicone hydrogel (SiHy...
متن کاملThe study of Lysozyme adsorption onto 2-hydroxyethylmethacrylates and Silicon Hydrogel Contact Lenses
In order to increase the water content and the oxygen permeability of hydrogels used in themanufacture of contact lenses, the polar monomer Silicon Hydrogel Contact Lenses (SHCL), and 2-hydroxyethyl methacrylate (HEMA) were copolymerized with the hydrogels. Due to the presence ofpolar monomers in the conventional contact lenses, the major component of the human tear,lysozyme is extensively adso...
متن کاملBiological and Clinical Implications of Lysozyme Deposition on Soft Contact Lenses
Within a few minutes of wear, contact lenses become rapidly coated with a variety of tear film components, including proteins, lipids, and mucins. Tears have a rich and complex composition, allowing a wide range of interactions and competitive processes, with the first event observed at the interface between a contact lens and tear fluid being protein adsorption. Protein adsorption on hydrogel ...
متن کاملAdsorption of human tear lipocalin to human meibomian lipid films.
PURPOSE Tear lipocalin (Tlc) is a major lipid binding protein in tears and is thought to have an important role in stabilizing the Meibomian lipid layer by transferring lipids to it from the aqueous layer or ocular surface, or by adsorbing to it directly. These possible roles have been investigated in vitro using human Tlc. METHODS Tlc was purified from human tears by size exclusion chromatog...
متن کاملTear film, contact lens, and patient factors associated with corneal staining.
PURPOSE The purpose of this study was to examine ocular surface and tear film, contact lens, care solution, medical, and patient-related factors that are associated with corneal staining in contact lens wearers. METHODS In this cross-sectional/nested case-control study, in addition to the assessment of corneal staining with fluorescein, a variety of tear film and ocular surface, contact lens,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 49 1 شماره
صفحات -
تاریخ انتشار 2008