The paper deals with the design of experiments for manipulator geometric and elastostatic calibration based on the test-pose approach. The main attention is paid to the efficiency improvement of numerical techniques employed in the selection of optimal measurement poses for calibration experiments. The advantages of the developed technique are illustrated by simulation examples that deal with the geometric calibration of the industrial robot of serial architecture.
منابع مشابه
Geometric calibration of industrial robots using enhanced partial pose measurements and design of experiments
The paper deals with geometric calibration of industrial robots and focuses on reduction of the measurement noise impact by means of proper selection of the manipulator configurations in calibration experiments. Particular attention is paid to the enhancement of measurement and optimization techniques employed in geometric parameter identification. The developed method implements a complete and...
متن کاملEstimation and Calibration of Robot Link Parameters with Intelligent Techniques
Abstract: Using robot manipulators for high accuracy applications require precise value of the kinematics parameters. Since measurement of kinematics parameters are usually associated with errors and accurate measurement of them is an expensive task, automatic calibration of robot link parameters makes the task of kinematics parameters determination much easier. In this paper a simple and easy ...
متن کاملA New Approach to Self-Localization for Mobile Robots Using Sensor Data Fusion
This paper proposes a new approach for calibration of dead reckoning process. Using the well-known UMBmark (University of Michigan Benchmark) is not sufficient for a desirable calibration of dead reckoning. Besides, existing calibration methods usually require explicit measurement of actual motion of the robot. Some recent methods use the smart encoder trailer or long range finder sensors such ...
متن کاملRobot Calibration Using a 3d Vision-based Measurement System
This work presents techniques for modeling and performing robot calibration processes under off-line programming using a 3-D vision-based measurement system. Kinematic modeling follows a singularity-free concept. The measurement system consists of a single CCD camera mounted on the robot tool flange and uses space resection models to measure the robot endeffector pose relative to a world coordi...
متن کاملThe Calibration Index and Taxonomy for Robot Kinematic Calibration Methods
The major approaches toward kinematic calibration are unified by considering an end-point measurement system as forming a joint and closing the kinematic loop. A calibration index is introduced, based on the mobility equation, that considers sensed and unsensed joints and single and multiple loops and expresses the surplus of measurements over degrees of freedom at each pose. Past work using op...