Deformability measurement of red blood cells using a microfluidic channel array and an air cavity in a driving syringe with high throughput and precise detection of subpopulations.

نویسندگان

  • Yang Jun Kang
  • Young-Ran Ha
  • Sang-Joon Lee
چکیده

Red blood cell (RBC) deformability has been considered a potential biomarker for monitoring pathological disorders. High throughput and detection of subpopulations in RBCs are essential in the measurement of RBC deformability. In this paper, we propose a new method to measure RBC deformability by evaluating temporal variations in the average velocity of blood flow and image intensity of successively clogged RBCs in the microfluidic channel array for specific time durations. In addition, to effectively detect differences in subpopulations of RBCs, an air compliance effect is employed by adding an air cavity into a disposable syringe. The syringe was equally filled with a blood sample (V(blood) = 0.3 mL, hematocrit = 50%) and air (V(air) = 0.3 mL). Owing to the air compliance effect, blood flow in the microfluidic device behaved transiently depending on the fluidic resistance in the microfluidic device. Based on the transient behaviors of blood flows, the deformability of RBCs is quantified by evaluating three representative parameters, namely, minimum value of the average velocity of blood flow, clogging index, and delivered blood volume. The proposed method was applied to measure the deformability of blood samples consisting of homogeneous RBCs fixed with four different concentrations of glutaraldehyde solution (0%-0.23%). The proposed method was also employed to evaluate the deformability of blood samples partially mixed with normal RBCs and hardened RBCs. Thereafter, the deformability of RBCs infected by human malaria parasite Plasmodium falciparum was measured. As a result, the three parameters significantly varied, depending on the degree of deformability. In addition, the deformability measurement of blood samples was successfully completed in a short time (∼10 min). Therefore, the proposed method has significant potential in deformability measurement of blood samples containing hematological diseases with high throughput and precise detection of subpopulations in RBCs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-throughput and label-free parasitemia quantification and stage differentiation for malaria-infected red blood cells.

This work reports a high throughput and label-free microfluidic cell deformability sensor for quantitative parasitemia measurement and stage determination for Plasmodium falciparum-infected red blood cells (Pf-iRBCs). The sensor relies on differentiating the RBC deformability (a mechanical biomarker) that is highly correlated with the infection status. The cell deformability is measured by eval...

متن کامل

Onm-21: General Principles of Collecting and Storing Cord Blood Stem Cell

Cord blood is the blood that remains in the umbilical cord and placenta following birth, which is usually discarded It contains red blood cells, white blood cells, platelets, and plasma, like blood. In addition, cord blood is a rich source of stem cells that may have potentially lifesaving benefits for your baby and family. The cord blood of baby serves as an abundant source of stem cells. Thes...

متن کامل

Parallel recognition of cancer cells using an addressable array of solid-state micropores.

Early stage detection and precise quantification of circulating tumor cells (CTCs) in the peripheral blood of cancer patients are important for early diagnosis. Early diagnosis improves the effectiveness of the therapy and results in better prognosis. Several techniques have been used for CTC detection but are limited by their need for dye tagging, low throughput and lack of statistical reliabi...

متن کامل

A Microfluidic Cross-Slot Device for Measurement of Erythrocyte Deformability

Red blood cell (RBC) deformation is a dominant factor in the rheological properties of blood in vessels smaller than 300 micrometers. A reduction in cell deformability is associated with health conditions such as malaria and diabetes. The extensional flow within a microfluidic cross-slot microchannel has been proposed as a mechanism for measuring the deformation of cells. Three-dimensional simu...

متن کامل

Dynamic deformability of sickle red blood cells in microphysiological flow.

In sickle cell disease (SCD), hemoglobin molecules polymerize intracellularly and lead to a cascade of events resulting in decreased deformability and increased adhesion of red blood cells (RBCs). Decreased deformability and increased adhesion of sickle RBCs lead to blood vessel occlusion (vaso-occlusion) in SCD patients. Here, we present a microfluidic approach integrated with a cell dimension...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 141 1  شماره 

صفحات  -

تاریخ انتشار 2016