Comparative study of accuracy and clinical agreement of the CoaguChek XS portable device versus standard laboratory practice in unexperienced patients.
نویسندگان
چکیده
The objective of the study was to compare the accuracy and clinical agreement of the CoaguChek XS versus the standard laboratory practice. Forty-one patients on long-term anticoagulation with acenocumarol without previous experience in self-monitoring participated to obtain 218 pairs of data. Several methods for comparative statistics were applied to assess the possible disagreements between techniques as well as a range of previously published criteria of clinical agreement and the very recently described error-grid for INR comparison that we partially modify. The mean age was 52.1 and the indications for oral anticoagulation were prosthetic valves (36.59%), atrial fibrillation (34.15%), venous thromboembolic disease (21.95%) and others (7.31%) with a target range of 2-3 INR units (63.4%) or 2.5-3.5 (36.6%). Analyzing the whole series of data, the Pearsons rho correlation coefficient for precision between methods was 0.95 and the C(b) bias correction factor for accuracy 0.99 with a minimal bias of 0.1 INR units between methods applying the Bland-Altman plot. The linear regression procedure described by Passing and Bablok showed a minimal deviation from the best-fit line and a slope of 0.90. The mean of the absolute relative differences was 7% which is in the "very good" range of agreement. No results were found in the clinically "dangerous" D zone of the error-grids with 99% of data in the clinically irrelevant and low relevant areas A and B. In this study self-management with the CoaguChek XS was clinically safe and reliable.
منابع مشابه
Clinical Utility and Accuracy of Coaguchek XS, a Reliable Alternative to Laboratory International Normalized Ratio Monitoring in Korean Patients With Atrial Fibrillation
Background and Objectives: To evaluate the accuracy and the clinical utility of the Coaguchek XS, a portable point-of-care coagulometer, compared to standard laboratory methods in Korean patients. Subjects and Methods: We included 107 patients with atrial fibrillation on long-term oral warfarin therapy. The prothrombin time as expressed by the international normalized ratio (INR) was measured b...
متن کاملTitle: Accuracy and clinical utility of the CoaguChek XS portable international normalised ratio monitor in a pilot study of warfarin home-monitoring Running title: Evaluation of the CoaguChek XS
Aim: To evaluate the accuracy of the CoaguChek XS international normalised ratio (INR) monitor compared to the laboratory method. Methods: The accuracy and ease of use of the recently marketed CoaguChek XS portable INR monitor was evaluated in 17 patients involved in a trial of warfarin home-monitoring. INR results from the monitor were compared to the laboratory method. Clinical applicability ...
متن کاملValidation of the CoaguChek XS international normalised ratio point-of-care analyser in patients at Charlotte Maxeke Johannesburg Academic Hospital, South Africa.
BACKGROUND Measurement of the international normalised ratio (INR) is essential in the management of patients on long-term warfarin therapy. The CoaguChek XS portable coagulometer is a point-of-care test for INR measurement. It offers the advantage of improved patient accessibility, particularly in peripheral clinics. OBJECTIVES To evaluate the clinical utility of the CoaguChek XS for monitor...
متن کاملSelf-monitoring of oral anticoagulation therapy in children.
This study aimed to investigate the accuracy of home International Normalized Ratio (INR) self-monitoring in pediatric patients on long-term oral anticoagulation therapy. Statistical and clinical agreement of INR values from capillary whole blood samples measured by 2 different portable prothrombin time monitors (CoaguChek S and XS) and venous blood samples measured by a laboratory coagulation ...
متن کاملAccuracy of the CoaguChek XS for point-of-care international normalized ratio (INR) measurement in children requiring warfarin.
Point-of-care INR (POC INR) meters can provide a safe and effective method for monitoring oral vitamin K antagonists (VKAs) in children. Stollery Children's Hospital has a large POC INR meter loan program for children requiring oral VKAs. Our protocol requires that POC INR results be compared to the standard laboratory INR for each child on several consecutive tests to ensure accuracy of CoaguC...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Thrombosis and haemostasis
دوره 101 5 شماره
صفحات -
تاریخ انتشار 2009