False-Positive Findings on Myocardial Perfusion SPECT
نویسندگان
چکیده
TO THE EDITOR: Recently, there have been 3 articles (1–3) published in The Journal of Nuclear Medicine attempting to define various artifactual sources that contribute to the unacceptably high rate of myocardial perfusion SPECT (MPS) studies with falsepositive findings. Each article suggests a different protocol modification intended to reduce the incidence of false-positive MPS findings. The first paper (2) suggests a 15-min wait before initiation of poststress thallium SPECT. The second paper (3) concludes that 360° SPECT acquisition is superior to 180° acquisition, thereby doubling the acquisition time. The most recent paper (1) proposes that additional poststress prone images, commenced 20–40 min after reclining the patient for supine imaging, result in MPS interpretations that correlate more accurately with the clinical outcome. We suggest an alternative and consistent explanation for the diagnostic improvements described in these studies. All 3 papers present protocol modifications that coincidentally result in an additional “equilibration” period during which the patient is supine. Thus, the diagnostic improvements demonstrated in all 3 of these papers could alternatively be concluded to be the result of the additional delay or prolongation that is inadvertently introduced by each of these protocols. More thorough development of the methodologies described in all 3 papers could have redirected the authors to very different conclusions from those presented. We suggested alternative approaches in previous letters to the editor about the 2 earlier papers (2,3). In the case of the most recent paper (1), Hayes et al. could have conclusively demonstrated the validity of prone imaging if they had simply chosen to randomize the order in which the prone and supine imaging sequences were performed. Unfortunately, this work as presented indicates that none of their patients underwent prone imaging before supine imaging. Because the authors chose not to alternate the order of their poststress supine and prone acquisitions, we are left with the possibility that it was actually the 20-min delay before the onset of prone imaging, not the prone versus supine position of the patient, that gave rise to the benefits shown by their data. In a guest editorial that appears immediately following (1), Lee et al. (4) weakly support the work of Hayes et al. by indicating that they “might use additional prone imaging” until attenuation correction achieves “robust results.” Attenuationinduced artifacts are often described to be the nemesis of rotational SPECT, but neither attenuation correction nor prone imaging is widely used in practice because prolongation of the acquisition is not a welcome encumbrance in most busy clinical imaging laboratories. Furthermore, we submit that when the patient is reproducibly positioned and 99mTc agents are used for both stress and rest images, and time is allowed after reclination for volumetric equilibration to be complete, there should be little if any artifactual stress/rest difference in MPS images due to attenuation. This leads us to wonder why additional resting prone images have not also been proposed as beneficial. It also remains true that even the application of “robust” attenuation correction using sequential CT/SPECT transmission/emission myocardial perfusion tomography has not been shown to consistently eliminate the elusive “diaphragmatic attenuation” artifacts. All of this further supports our contention that another phenomenon is the dominant factor in generating false-positive MPS findings, namely, ventricular volume changes that occur during image acquisition when begun too soon after reclination of the patient. Positional changes (upright to supine) and poststress dynamic changes in the volume of the human left ventricle are well documented in the cardiac physiology literature. In our previous work (5), we have graphically and statistically described the changes in left ventricular volume that occur during the 20 min following graded treadmill exercise and reclination of the patient for imaging. On the basis of these measurements, we propose that it is primarily these dynamic, positionally dependent ventricular volume changes that are the dominant factor generating artifacts when sequential, rotational SPECT images are reconstructed using standard, commercially available software. Until we fully comprehend the complexity of the myocardial perfusion imaging problem and design nonrotational SPECT systems (6) that accommodate its most demanding aspects, it will be difficult to advance the state of the art in nuclear cardiology to any higher level of clinical utility than is currently achieved by rotational SPECT systems.
منابع مشابه
The value of the Gated 99mTc-MIBI SPECT in differentiation of fixed myocardial lesions [Persian]
Fixed myocardial defects in both stress and rest images, could be artifactual as a result of soft tissue attenuation. To increase specificity and identify the false positive results, we used gated technique to evaluate the wall motion and wall thickening as an index to differentiate real ischemic lesions from artifactual defects. 93 patients were studied. In 46 patients (48.8%) fixed perf...
متن کاملGated 99mTc-MIBI myocardial perfusion SPECT in patients with right bundle branch block but without evidence of coronary artery disease
Introduction: We aimed to investigate the effect of right bundle branch block (RBBB) on perfusion and functional parameters in dipyridamole stress/rest Tc99m-MIBI gated myocardial perfusion SPECT (GSPECT) which may be helpful in interpretation of myocardial perfusion imaging. Methods: We studied 73 patients with low pre-test likelihood of coronary artery disease in two groups: 38 patients wit...
متن کاملThe truncation artifact in a skinny patient following myocardial perfusion SPECT
Myocardial perfusion SPECT is one of the most common imaging techniques performed in nuclear medicine departments. To avoid misleading interpretation, it is necessary to address the quality control and technical problems. The truncation artifact occurs when the patient size is large relative to the field of view of the camera, causing false perfusion defects in the LV myocardium, misinterpreted...
متن کاملAttenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]
Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...
متن کاملCovid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT
A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...
متن کاملGated myocardial perfusion SPECT in patients with left bundle block but having low probability of coronary artery disease; as compared to the patients with normal electrocardiogram
Introduction: We aimed to investigate of effect of left bundle branch block (LBBB) on perfusion and functional parameters in dipyridamole Tc99m-MIBI gated myocardial perfusion SPECT which may be helpful in interpretation of myocardial perfusion imaging. Methods: We studied 70 patients with low pre-test probability of coronary artery disease in two groups: 35 patients with LBBB and 35 subject...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004