Standardization of milk mid-infrared spectrometers for the transfer and use of multiple models.

نویسندگان

  • C Grelet
  • J A Fernández Pierna
  • P Dardenne
  • H Soyeurt
  • A Vanlierde
  • F Colinet
  • C Bastin
  • N Gengler
  • V Baeten
  • F Dehareng
چکیده

An increasing number of models are being developed to provide information from milk Fourier transform mid-infrared (FT-MIR) spectra on fine milk composition, technological properties of milk, or even cows' physiological status. In this context, and to take advantage of these existing models, the purpose of this work was to evaluate whether a spectral standardization method can enable the use of multiple equations within a network of different FT-MIR spectrometers. The piecewise direct standardization method was used, matching "slave" instruments to a common reference, the "master." The effect of standardization on network reproducibility was assessed on 66 instruments from 3 different brands by comparing the spectral variability of the slaves and the master with and without standardization. With standardization, the global Mahalanobis distance from the slave spectra to the master spectra was reduced on average from 2,655.9 to 14.3, representing a significant reduction of noninformative spectral variability. The transfer of models from instrument to instrument was tested using 3 FT-MIR models predicting (1) the quantity of daily methane emitted by dairy cows, (2) the concentration of polyunsaturated fatty acids in milk, and (3) the fresh cheese yield. The differences, in terms of root mean squared error, between master predictions and slave predictions were reduced after standardization on average from 103 to 17 g/d, from 0.0315 to 0.0045 g/100 mL of milk, and from 2.55 to 0.49 g of curd/100 g of milk, respectively. For all the models, standard deviations of predictions among all the instruments were also reduced by 5.11 times for methane, 5.01 times for polyunsaturated fatty acids, and 7.05 times for fresh cheese yield, showing an improvement of prediction reproducibility within the network. Regarding the results obtained, spectral standardization allows the transfer and use of multiple models on all instruments as well as the improvement of spectral and prediction reproducibility within the network. The method makes the models universal, thereby offering opportunities for data exchange and the creation and use of common robust models at an international level to provide more information to the dairy sector from direct analysis of milk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Milk Adulteration Using MID-IR Spectroscopy – A Review

This paper presents the review on different types of milk adulteration based upon conventional method. A straight forward and quick strategy for measurement of milk adulteration has been developed using mid-infrared (MIR) spectrometers. Milk samples was purchased from local supermarkets and spiked with tap water, hydrogen peroxide, glucose, urea and formaldehyde in different concentrations in m...

متن کامل

I-18: Techniques and Technologies for Embryo Transfer: Does It Really Matter.

The learning objectives of this presentation are to understand the dynamics involved in the process of ET, evaluate the evidence for/against common practices and techniques and develop a standardized ET process in view of supporting evidence. Gametes and embryos are handled with extreme care at every step of the Laboratory process. ET is the least sophisticated step of the in vitro Fertilizatio...

متن کامل

Assessing fertility and welfare of dairy cows through novel mid-infrared milk- based biomarkers

<1 line> Although herd management and, more recently, selection have mitigated partially the deterioration of functional traits, these efforts are still hampered by the difficulties in direct recording of sufficient relevant phenotypes. Recent advances in the use of mid-infrared (MIR) spectroscopy, as the standardization of apparatuses, has led to the highly portable deployment...

متن کامل

Comparison of Benchtop Fourier-Transform (FT) and Portable Grating Scanning Spectrometers for Determination of Total Soluble Solid Contents in Single Grape Berry (Vitis vinifera L.) and Calibration Transfer

Near-infrared (NIR) spectroscopy was applied for the determination of total soluble solid contents (SSC) of single Ruby Seedless grape berries using both benchtop Fourier transform (VECTOR 22/N) and portable grating scanning (SupNIR-1500) spectrometers in this study. The results showed that the best SSC prediction was obtained by VECTOR 22/N in the range of 12,000 to 4000 cm-1 (833-2500 nm) for...

متن کامل

مقایسه دو مدل رگرسیون تصادفی تک صفتی و چند صفتی در برآورد پارامترهای ژنتیکی صفات تولیدی در گاوهای شیری هلشتاین

  In this research test-day records of milk, fat and protein yields of first lactation of 11368 Holstein cows were used to comparison of estimated genetic parameters by restricted maximum likelihood method based on single trait and multiple trait random regression models. These data were collected from 133 herds during 2001 to 2010 by Cattle Breeding and Dairy Product Improvement Center. Herita...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of dairy science

دوره 100 10  شماره 

صفحات  -

تاریخ انتشار 2017