Use of Nanocrystalline Hydroxyapatite With Autologous BMA and Local Bone in the Lumbar Spine
نویسندگان
چکیده
STUDY DESIGN A retrospective, multicenter, medical record review and independent analysis of computed tomographic scans was performed in 46 patients to determine radiographic arthrodesis rates after 1-segment, 2-segment, or 3-segment instrumented posterolateral fusions (PLF) using autograft, bone marrow aspirate (BMA), and a nanocrystalline hydroxyapatite bone void filler (nHA). OBJECTIVE To determine the radiographic arthrodesis rates after instrumented lumbar PLF using local autograft, BMA, and nHA. SUMMARY OF BACKGROUND DATA The use of iliac crest autograft in posterolateral spine fusion carries real and significant risks. Many forms of nanocrystalline hydroxyapatite have been studied in various preclinical models, but no human studies have reviewed its efficacy as a bone graft supplement in PLF. METHODS Posterolateral arthrodesis progression was documented approximately 12 months postoperatively using a computed tomographic scan and evaluated by an independent radiologist for the presence of bridging bone. One-year postoperative clinical outcomes were assessed using the PROLO score. RESULTS Radiographically, 91% patients treated exhibited bilateral or unilateral posterolateral bridging bone. Ninety-four percent of the segments treated exhibited bilateral or unilateral posterolateral bridging bone, whereas 6% segments exhibited no posterolateral bridging bone on either side. A total of 93% individual sites treated exhibited posterolateral bridging bone. In 1-segment, 2-segment, and 3-segment arthrodesis, 88%, 93%, and 100%, respectively, of individual sites exhibited radiographic bridging bone. One-year postoperative PROLO scores for 77% patients were excellent or good. There were no complications related to the posterolateral graft mass and no symptomatic nonunions. CONCLUSIONS The arthrodesis rates after instrumented lumbar fusion using local autograft mixed with BMA and the nHA is equivalent to the rates reported for iliac crest autograft in these indications, including stringent indications, such as 3-segment procedures. By approximately 12 months postoperatively, there was no significant difference in the rates of bridging bone between the 1-segment, 2-segment, and 3-segment procedures.
منابع مشابه
A comparative study of radiographic results using HEALOS collagen-hydroxyapatite sponge with bone marrow aspiration versus local bone graft in the same patients undergoing posterolateral lumbar fusion.
BACKGROUND Autologous bone harvested from the iliac crest is the gold standard for lumbar spinal fusion. However postoperative donor site pain and morbidity have been reported. Local bone graft is insufficient and contains some soft-tissue attachment. Therefore, Healos (DePuy Spine, Raynham, MA, USA) is currently bone graft substitute that was introduced for spinal fusion with good results but ...
متن کاملClinical and radiographic outcomes of extreme lateral approach to interbody fusion with β-tricalcium phosphate and hydroxyapatite composite for lumbar degenerative conditions
BACKGROUND Historically, iliac crest bone graft has been used as the graft of choice for lumbar spine fusion procedures. Because fusion techniques have become less invasive, the demand for minimally disruptive grafting options has increased. This prospective study was performed to assess clinical and radiographic outcomes of patients treated with an iliac crest bone graft alternative and latera...
متن کاملThe Correlation between Trabecular Bone Score and Lumbar Spine Bone Mineral Density in Patients with Normal and High Body Mass Index
Background: Trabecular bone score (TBS) measures the underlying quality of bone texture using dual-energy X-ray absorptiometry (DXA) images. The present study aimed to investigate the correlation between lumbar spine bone mineral density (BMD) and TBS, and subsequently determine whether the association varies with the body mass index (BMI). Methods: Data from 548 patients were collected a...
متن کاملComparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus
The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...
متن کاملComparison of Bone Mineral Density in Lumbar Spine between Athletic and Non-Athletic Premenopausal Women
Background & Aims: The purpose of the present research was to compare the bone mineral density (BMD) of lumbar spine between athletic and non-athletic premenopausal women. Methods: Fifteen female athletes (runner) with the mean age of 33.80 ± 4.81 years, mean height of 164.13 ± 5.31 cm, mean weight of 57.33 ± 4.22 kg, and mean body mass index (BMI) of 21.41 ± 2.21 kg/m2 and 15 female non-athlet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 30 شماره
صفحات -
تاریخ انتشار 2017