Reliability and validity of ultrasound measurements of muscle fascicle length and pennation in humans: a systematic review.

نویسندگان

  • Li Khim Kwah
  • Rafael Z Pinto
  • Joanna Diong
  • Robert D Herbert
چکیده

Ultrasound imaging is widely used to measure architectural features of human skeletal muscles in vivo. We systematically reviewed studies of the reliability and validity of two-dimensional ultrasound measurement of muscle fascicle lengths or pennation angles in human skeletal muscles. A comprehensive search was conducted in June 2011. Thirty-six reliability studies and six validity studies met the inclusion criteria. Data from these studies indicate that ultrasound measurements of muscle fascicle lengths are reliable across a broad range of experimental conditions [intraclass correlation coefficient (ICC) and r values were always > 0.6, and coefficient of variation values were always < 10%]. The reliability of measurements of pennation angles is broadly similar (ICC and r values were always > 0.5 and coefficient of variation values were always < 14%). Data on validity are less extensive and probably less robust, but suggest that measurement of fascicle lengths and pennation angles are accurate (ICC > 0.7) under certain conditions, such as when large limb muscles are imaged in a relaxed state and the limb or joint remains stationary. Future studies on validity should consider ways to test for the validity of two-dimensional ultrasound imaging in contracted or moving muscles and the best method of probe alignment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between sprint performance of front-crawl swimming and muscle fascicle length in young swimmers

The purpose of this study was to investigate the relationship between sprint performance of front-crawl swimming and muscle fascicle length in 23 male young swimmers. The sample was divided into two groups by 25-m sprint front-crawl swimming performance: 14.6-15.7 s (S1, n=11) and 15.8-17 s (S2, n=12). Muscle thickness and pennation angle and fascicle length of the Biceps Brachii (only muscle t...

متن کامل

Inter-rater reliability and measurement error of sonographic muscle architecture assessments.

OBJECTIVES Sonography of muscle architecture provides physicians and researchers with information about muscle function and muscle-related disorders. Inter-rater reliability is a crucial parameter in daily clinical routines. The aim of this study was to assess the inter-rater reliability of sonographic muscle architecture assessments and quantification of errors that arise from inconsistent pro...

متن کامل

Effect of Transducer Orientation on Errors in Ultrasound Image-Based Measurements of Human Medial Gastrocnemius Muscle Fascicle Length and Pennation

Ultrasound imaging is often used to measure muscle fascicle lengths and pennation angles in human muscles in vivo. Theoretically the most accurate measurements are made when the transducer is oriented so that the image plane aligns with muscle fascicles and, for measurements of pennation, when the image plane also intersects the aponeuroses perpendicularly. However this orientation is difficult...

متن کامل

Ultrasound evaluation in combination with finger extension force measurements of the forearm musculus extensor digitorum communis in healthy subjects

BACKGROUND The aim of this study was to evaluate the usefulness of an ultrasound-based method of examining extensor muscle architecture, especially the parameters important for force development. This paper presents the combination of two non-invasive methods for studying the extensor muscle architecture using ultrasound simultaneously with finger extension force measurements. METHODS M. exte...

متن کامل

systematic review of the characteristics of ultrasound measurements in the evaluation of spinal curvatures in scoliosis patients

Abstract Aims: Scoliosis is one of the secondary complications in amputation veterans, which requires periodic evaluations. The gold standard for evaluating the spine is radiography, which has caused many concerns due to the very high doses of X-ray radiation. For this reason, therapists are finding for an alternative method for this tool, so ultrasound is a non-invasive tool with different me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 114 6  شماره 

صفحات  -

تاریخ انتشار 2013