Characterization of contact force during endocardial and epicardial ventricular mapping.

نویسندگان

  • Laurence Jesel
  • Frédéric Sacher
  • Yuki Komatsu
  • Matthew Daly
  • Stephan Zellerhoff
  • Han S Lim
  • Nicolas Derval
  • Arnaud Denis
  • Wislane Ambri
  • Khaled Ramoul
  • Valérie Aurillac
  • Mélèze Hocini
  • Michel Haïssaguerre
  • Pierre Jaïs
چکیده

BACKGROUND The optimal contact force (CF) for ventricular mapping and ablation remains unvalidated. We assessed CF in different endocardial and epicardial regions during ventricular tachycardia substrate mapping using a CF-sensing catheter (Smartouch; Biosense-Webster) and compared the transseptal versus retroaortic approach. METHODS AND RESULTS In total, 8979 mapping points with CF, and force vector orientation (VO) were recorded in 21 patients, comprising 13 epicardial, 12 left ventricular (6 transseptal and 6 retroaortic approach), and 12 right ventricular endocardial maps. VO was defined as adequate when the vector was directed toward the myocardium. During epicardial mapping, 46% of the points showed an adequate VO and a median CF of 8 (4-13) g, however, with significant differences among the 8 regions. When VO was inadequate, median CF was higher at 16 (10-24) g (P<0.0001). During left ventricular and right ventricular endocardial mapping, 94% of VO were adequate. Median CF of adequate VO was higher in the left ventricular and right ventricular endocardium than in the epicardium (15 [8-25] and 13 [7-22] g versus 8 [4-13] g, respectively; both P<0.001). Global median left ventricular CF with transseptal approach was not statistically different from retroaortic approach, but CF in the apicoinferior and apicoseptal regions was higher with transseptal approach (P<0.001). CONCLUSIONS Ventricular mapping demonstrates important regional variations in CF, but in general, CF is higher endocardially than epicardially where poor catheter orientation is associated with higher CF. A transseptal approach may lead to improved contact particularly in the apicoseptal and inferior regions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined epicardial and endocardial electroanatomic mapping in a porcine model of healed myocardial infarction.

BACKGROUND Substrate mapping of post-myocardial infarction ventricular tachycardia involves electroanatomic delineation of scarred tissue on the basis of electrogram characteristics during sinus rhythm. A percutaneous transthoracic technique was recently described that allows catheter mapping of the epicardial surface of the heart. This study sought to determine whether the epicardial extent of...

متن کامل

Epicardial and endocardial activation during sustained ventricular tachycardia in man.

Ventricular activation during ventricular tachycardia was studied by intraoperative epicardial and endocardial mapping in 21 patients with coronary artery disease and previous myocardial infarction who underwent operation for recurrent ventricular tachycardia. Twenty-nine morphologically distinct tachycardias were mapped; 18 tachycardias had a right bundle branch block morphology and 11 had a l...

متن کامل

Comparison of Endocardial Catheter Mapping with Intraoperative Mapping of Ventricular Tachyeardia

To validate the accuracy of catheter endocardial mapping to localize the origin of ventricular tachycardia (VT), we compared catheter endocardial mapping with intraoperative epicardial and endocardial mapping of 24 morphologically distinct VTs in 18 patients undergoing surgery. Twelve had VT with left bundle branch block morphology and 12 had VT with right bundle branch block morphology. Cathet...

متن کامل

The first human experience of a contact force sensing catheter for epicardial ablation of ventricular tachycardia

Contact force (CF) is one of the major determinants for sufficient lesion formation. CF-guided procedures are associated with enhanced lesion formation and procedural success. We report our initial experience in epicardial ventricular tachycardia (VT) ablation with a force-sensing catheter using a new approach with an angioplasty balloon. Two patients with arrhythmogenic right ventricular cardi...

متن کامل

Simultaneous Epicardial and Noncontact Endocardial Mapping of the Canine Right Atrium: Simulation and Experiment

Epicardial high-density electrical mapping is a well-established experimental instrument to monitor in vivo the activity of the atria in response to modulations of the autonomic nervous system in sinus rhythm. In regions that are not accessible by epicardial mapping, noncontact endocardial mapping performed through a balloon catheter may provide a more comprehensive description of atrial activi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 7 6  شماره 

صفحات  -

تاریخ انتشار 2014