Open-source, small-animal magnetic resonance-guided focused ultrasound system

نویسندگان

  • Megan E Poorman
  • Vandiver L Chaplin
  • Ken Wilkens
  • Mary D Dockery
  • Todd D Giorgio
  • William A Grissom
  • Charles F Caskey
چکیده

BACKGROUND MR-guided focused ultrasound or high-intensity focused ultrasound (MRgFUS/MRgHIFU) is a non-invasive therapeutic modality with many potential applications in areas such as cancer therapy, drug delivery, and blood-brain barrier opening. However, the large financial costs involved in developing preclinical MRgFUS systems represent a barrier to research groups interested in developing new techniques and applications. We aim to mitigate these challenges by detailing a validated, open-source preclinical MRgFUS system capable of delivering thermal and mechanical FUS in a quantifiable and repeatable manner under real-time MRI guidance. METHODS A hardware and software package was developed that includes closed-loop feedback controlled thermometry code and CAD drawings for a therapy table designed for a preclinical MRI scanner. For thermal treatments, the modular software uses a proportional integral derivative controller to maintain a precise focal temperature rise in the target given input from MR phase images obtained concurrently. The software computes the required voltage output and transmits it to a FUS transducer that is embedded in the delivery table within the magnet bore. The delivery table holds the FUS transducer, a small animal and its monitoring equipment, and a transmit/receive RF coil. The transducer is coupled to the animal via a water bath and is translatable in two dimensions from outside the magnet. The transducer is driven by a waveform generator and amplifier controlled by real-time software in Matlab. MR acoustic radiation force imaging is also implemented to confirm the position of the focus for mechanical and thermal treatments. RESULTS The system was validated in tissue-mimicking phantoms and in vivo during murine tumor hyperthermia treatments. Sonications were successfully controlled over a range of temperatures and thermal doses for up to 20 min with minimal temperature overshoot. MR thermometry was validated with an optical temperature probe, and focus visualization was achieved with acoustic radiation force imaging. CONCLUSIONS We developed an MRgFUS platform for small-animal treatments that robustly delivers accurate, precise, and controllable sonications over extended time periods. This system is an open source and could increase the availability of low-cost small-animal systems to interdisciplinary researchers seeking to develop new MRgFUS applications and technology.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors

Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...

متن کامل

A high precision MR-compatible positioning system for focused ultrasound experiments in small animal models

Introduction: Magnetic resonance guided focused ultrasound (MRgFUS) therapy is a non-invasive technique for targeted blood-brain barrier disruption, site-specific delivery of pharmaceuticals, and controlled heating and coagulation of tissues [1, 2]. However, the translation of this technology into clinical practice still requires extensive testing in preclinical rodent models, yet the small siz...

متن کامل

Open-Source Small-Animal MR-Guided Focused Ultrasound System

Figure 3: (a) Sample 20 minute, controlled sonication at 6 oC in a phantom. (b) Representative temperature map during an in vivo experiment overlayed on base image. 144 Open-Source Small-Animal MR-Guided Focused Ultrasound System Megan E Poorman, Vandiver L Chaplain, Ken Wilkens, Shantanu Majumdar, William A Grissom, and Charles F Caskey Biomedical Engineering, Vanderbilt University, Nashville,...

متن کامل

MatMRI and MatHIFU: software toolboxes for real-time monitoring and control of MR-guided HIFU

BACKGROUND The availability of open and versatile software tools is a key feature to facilitate pre-clinical research for magnetic resonance imaging (MRI) and magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) and expedite clinical translation of diagnostic and therapeutic medical applications. In the present study, two customizable software tools that were developed at the T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016