STATEMENT OF PROBLEM The external contour of an implant and the magnitude of occlusal loading can have significant effects on the load transfer characteristics and may result in different bone failure rates for different implant systems. PURPOSE The goal of this study was to investigate the effects of external geometry and occlusal load magnitude on bone failure modes for 5 commercially available dental implant systems. MATERIAL AND METHODS Five different implant systems; Ankylos, Astra, Bicon, ITI, and Nobel Biocare, comparable in size, but different in thread profile and crest module shapes, were compared using the finite element method. Type II bone quality was approximated and complete osseous integration was assumed. Occlusal loads of varying magnitudes (0 to 2000 N) were applied on the abutments supporting single tooth restorations at 11.3 degrees from the vertical axis with a 1-mm offset. Total overloaded bone area, where tensile and compressive normal stresses fell outside of the recommended limits of 100 and 170 MPa, respectively, was investigated for different load levels. RESULTS For moderate levels of occlusal loads up to 300 N, the compact bone was not overloaded by any of the implant systems. At the extreme end of the occlusal load range (1000 N or more) the overloading characteristics of implants may be dependent on geometric shape. CONCLUSION In general, overloading occurs near the superior region of compact bone, in compression, and it is primarily caused by the normal and lateral components of the occlusal load. At the region of intersection of compact and trabecular bone, overloading occurs in tension due to the vertical component of the occlusal load. For excessive forces greater than 1000 N, the overloaded areas of the bone varied considerably among 5 different implants systems evaluated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

Investigating the Performance of Cracked Asphalt Pavement Using Finite Elements Analysis

Occurrence of top down and bottom up fatigue cracking in asphaltic pavements is common. Conventional pavement analysis methods ignore the existence of cracks in asphaltic layers. However, it seems that the responses of cracked pavement would not be the same as a pavement without crack. This paper describes effects of crack type, position and length, and vehicles tire inflation pressure and axle...

متن کامل

Effect of Abutment Angulation and Material on Stress and Strain Distributions in Premaxillary Bone: A Three-Dimensional Finite Element Analysis

Background and Aim: Dental implants with angled abutments are often inserted in the anterior maxillary region due to the status of the residual ridge and aesthetic considerations. The purpose of this study was to assess stress and strain distributions in the premaxillary bone around dental implants by means of finite element analysis (FEA). Materials and Methods: Four three-dimensional (3D) fi...

متن کامل

Effect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis

This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...

متن کامل

Comparative Evaluation of Osseointegrated Dental Implants Based on Platform-Switching Concept: Influence of Diameter, Length, Thread Shape, and In-Bone Positioning Depth on Stress-Based Performance

This study aimed to investigate the influence of implant design (in terms of diameter, length, and thread shape), in-bone positioning depth, and bone posthealing crestal morphology on load transfer mechanisms of osseointegrated dental implants based on platform-switching concept. In order to perform an effective multiparametric comparative analysis, 11 implants different in dimensions and in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 92 6  شماره 

صفحات  -

تاریخ انتشار 2004