Safety and Efficacy of Everolimus- Versus Sirolimus-Eluting Stents: 5-Year Results From SORT OUT IV.

نویسندگان

  • Lisette Okkels Jensen
  • Per Thayssen
  • Evald Høj Christiansen
  • Michael Maeng
  • Jan Ravkilde
  • Knud Nørregaard Hansen
  • Henrik Steen Hansen
  • Lars Krusell
  • Anne Kaltoft
  • Hans Henrik Tilsted
  • Klara Berencsi
  • Anders Junker
  • Jens Flensted Lassen
چکیده

BACKGROUND Long-term safety and efficacy for everolimus-eluting stents (EES) versus those of sirolimus-eluting stents (SES) are unknown. OBJECTIVES This study compared 5-year outcomes for EES with those for SES from the SORT OUT IV (Scandinavian Organization for Randomized Trials with Clinical Outcome) trial. METHODS Five-year follow-up was completed for 2,771 patients (99.9%). Primary endpoint was a composite of major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), target vessel revascularization (TVR), and definite stent thrombosis. RESULTS At 5-years, MACE occurred in 14.0% and 17.4% in the EES and SES groups, respectively (hazard ratio [HR]: 0.80, 95% confidence interval [CI]: 0.66 to 0.97; p = 0.02). The MACE rate did not differ significantly within the first year (HR: 0.96, 95% CI: 0.71 to 1.19; p = 0.79), but from years 1 through 5, the MACE rate was lower with EES (HR: 0.71, 95% CI: 0.55 to 0.90; p = 0.006; p interaction = 0.12). Definite stent thrombosis was lower with EES (0.4%) than with SES (2.0%; HR: 0.18, 95% CI: 0.07 to 0.46), with a lower risk of very late definite stent thrombosis in the EES group (0.2% vs. 1.4%, respectively; HR: 0.16, 95% CI: 0.05 to 0.53). When censoring the patients at the time of stent thrombosis, we found no significant differences between the 2 stent groups for MACE rates (HR: 0.89, 95% CI: 0.73 to 1.08; p = 0.23), target lesion revascularization (HR: 0.90, 95% CI: 0.64 to 1.27; p = 0.55), and MI (HR: 0.93, 95% CI: 0.64 to 1.36; p = 0.72). CONCLUSIONS At 5-year follow-up, MACE rate was significantly lower with EES- than with SES-treated patients, due largely due to a lower risk of very late definite stent thrombosis. (Randomized Clinical Comparison of the Xience V and the Cypher Coronary Stents in Non-selected Patients With Coronary Heart Disease [SORT OUT IV]; NCT00552877).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-year outcomes after revascularization with everolimus- and sirolimus-eluting stents from the SORT OUT IV trial.

OBJECTIVES The study sought to compare the risk of late outcome with a focus on very late definite stent thrombosis of the everolimus-eluting stent (EES) with that of the sirolimus-eluting stent (SES) at 3-year follow-up. BACKGROUND In the SORT OUT IV (SORT OUT IV Trial), comparing the EES with the SES in patients with coronary artery disease, the EES was noninferior to the SES at 9 months. T...

متن کامل

Differential clinical responses to everolimus-eluting and Paclitaxel-eluting coronary stents in patients with and without diabetes mellitus.

BACKGROUND Some (but not all) prior trials have reported differential outcomes after percutaneous coronary intervention with paclitaxel-eluting stents versus stents eluting rapamycin analogs according to the presence of diabetes mellitus. These studies lacked sufficient power to examine individual safety and efficacy end points. METHODS AND RESULTS To determine whether an interaction exists b...

متن کامل

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

Baremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS

Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...

متن کامل

2-year patient-related versus stent-related outcomes: the SORT OUT IV (Scandinavian Organization for Randomized Trials With Clinical Outcome IV) Trial.

OBJECTIVES There are limited head-to-head randomized data on patient-related versus stent-related outcomes for everolimus-eluting stents (EES) and sirolimus-eluting stents (SES). BACKGROUND In the SORT OUT IV (Scandinavian Organization for Randomized Trials With Clinical Outcome IV) trial, comparing the EES with the SES in patients with coronary artery disease, the EES was noninferior to the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 67 7  شماره 

صفحات  -