A safe, low-cost and portable instrumentation for bedside time-resolved picosecond near infrared spectroscopy

نویسندگان

  • Marine Amouroux
  • Wilfried Uhring
  • Thierry Pebayle
  • Patrick Poulet
  • Luc Marlier
چکیده

Continuous wave Near InfraRed Spectroscopy (NIRS) has been used successfully in clinical environments for several years to detect cerebral activation thanks to oxymetry (i.e. absorption of photons by oxyand deoxyhemoglobin) measurement. The goal of our group is to build a clinically-adapted time-resolved NIRS setup i.e. a setup that is compact and robust enough to allow bedside measurements and that matches safety requirements with human patients applications. Indeed our group has already shown that time resolution allows spatial resolution and improves sensitivity of cerebral activation detection. The setup is built with four laser diodes (excitation wavelengths: 685, 780, 830 and 870 nm) whose emitted light is injected into four optical fibers; detection of reflected photons is made through an avalanche photodiode and a high resolution timing module used to record Temporal Point Spread Functions (TPSF). Validation of the device was made using cylindrically-chaped phantoms with absorbing and/or scattering inclusions. Results show that recorded TPSF are typical both of scattering and absorbing materials thus demonstrating that our apparatus would detect variation of optical properties (absorption and scattering) deep within a diffusive media just like a cerebral activation represents a rise of absorption in the cortex underneath head surface.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bedside monitoring of patients with shock using a portable spatially-resolved near-infrared spectroscopy.

Clinical monitoring of shock mainly depends on blood-oxygen-indices obtained from invasive blood sample tests. The central internal jugular central vein oxygenation level (ScvO2) has been considered as a gold standard indicator for shock prediction. We developed a noninvasive spatially-resolved near-infrared spectroscopy (SR-NIRS) to measure tissue blood oxygen saturation (StO2) surrounding the...

متن کامل

Localized near-infrared spectroscopy and functional optical imaging of brain activity.

Changes in cerebral blood flow (CBF) and cerebral metabolic rates (CMRO2) have been used as indices for changes in neuronal activity. Near-infrared spectroscopy (NIRS) can also measure cerebral haemodynamics and metabolic changes, enabling the possible use of multichannel recording of NIRS for functional optical imaging of human brain activity. Spatio-temporal variations of brain regions were d...

متن کامل

Modeling Time Resolved Light Propagation Inside a Realistic Human Head Model

Background: Near infrared spectroscopy imaging is one of the new techniques used for investigating structural and functionality of different body tissues. This is done by injecting light into the medium and measuring the photon intensity at the surface of the tissue.Method: In this paper the different medical applications, various imaging and simulation techniques of NIRS imaging is described. ...

متن کامل

Picosecond time-resolved cyclotron resonance of non-equilibrium carriers in semiconductors

We have investigated the intraband dynamics of non-equilibrium carriers in semiconductors, using a picosecond far-infrared (FIR) free-electron laser synchronized with a femtosecond near-infrared (NIR) Ti : sapphire laser. An intense NIR pulse creates carriers, which interact with a delayed FIR pulse. We detect time-resolved cyclotron resonance by monitoring the intensity of the transmitted and ...

متن کامل

Length-free near infrared measurement of newborn malnutrition

Under-nutrition in neonates can cause immediate mortality, impaired cognitive development and early onset adult disease. Body fat percentage measured using air-displacement-plethysmography has been found to better indicate under-nutrition than conventional birth weight percentiles. However, air-displacement-plethysmography equipment is expensive and non-portable, so is not suited for use in dev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009