Cardiac resynchronization therapy and implantable cardiac defibrillators in left ventricular systolic dysfunction.
نویسندگان
چکیده
OBJECTIVES To determine the efficacy, effectiveness, and safety of cardiac resynchronization therapy (CRT) and/or implantable cardioverter defibrillators (ICD) in patients with left ventricular systolic dysfunction (LVSD). DATA SOURCES A systematic and comprehensive literature search was conducted to identify randomized controlled trials (RCTs) evaluating efficacy and observational studies evaluating effectiveness or safety of CRT and/or ICD in patients with LVSD. REVIEW METHODS Study selection, quality assessment, and data extraction were completed by several investigators in duplicate and independently. Random-effects models were used for analyses. RESULTS From 11,340 citations, we identified 14 RCTs (4,420 patients) for the CRT efficacy review, 106 studies (9,209 patients) for the CRT effectiveness review, 89 studies (9,677 patients) for the CRT safety review, 12 RCTs (8,516 patients) for the ICD efficacy review, 48 studies (15,097 patients) for the ICD effectiveness review, and 49 studies (12,592 patients) for the ICD safety review-all studies enrolled only patients with LVSD. An additional 12 studies (68,848 patients) were included for an analysis of peri-implant outcomes for all patients with ICD (i.e., not only LVSD patients). All patients in the CRT studies had LVSD (mean LVEF from 21 to 30 percent) and prolonged QRS duration (mean from 155 to 209 msec), and 91 percent had New York Heart Association (NYHA) class III or IV symptoms. In patients with LVSD and heart failure symptoms, CRT improved ejection fraction (weighted mean difference 3.0 percent [95% CI, 0.9 to 5.1]), quality of life (weighted mean reduction in Minnesota Living with Heart Failure Questionnaire 8.0 points [95% CI, 5.6 to 10.4 points]), and function (59 percent of CRT recipients vs. 37 percent of controls improved by at least one NYHA class in the RCTs and between 63 percent and 82 percent of CRT recipients improved by at least one NYHA class in observational studies). The proportion of patients hospitalized for HF was reduced by 37 percent (95% CI, 7 to 57 percent) and all-cause mortality was reduced by 22 percent (95% CI, 9 to 33 percent; NNT=29 over 6 months). Implant success rate was 93 percent, 0.3 percent of patients with LVSD died during implantation. Over a median 11-month followup, 6.6 percent of CRT devices exhibited lead problems and 5 percent malfunctioned. In patients with LVSD, ICD reduced all-cause mortality by 20 percent (95% CI, 10 to 29 percent; NNT=20 over 35 months). ICD implant success rate was 99 percent and peri-implant deaths occurred in 1.2 percent of LVSD patients and 1.3 percent of all implantees. The frequency of post-implantation complications in LVSD patients per 100 patient years included 1.4 (95% CI, 1.2 to 1.6) device malfunctions, 1.5 (95% CI, 1.3 to 1.8) lead problems, 0.6 (95% CI, 0.5 to 0.8) implant site infections, and 19.1 (95% CI, 16.5 to 22.0) inappropriate discharges in RCT participants and 4.7 (95% CI, 4.3 to 5.1) inappropriate discharges in patients enrolled in observational studies. CONCLUSIONS ICD and CRT reduce all-cause mortality in patients with LVSD meeting RCT entry criteria. The incremental benefit of CRT plus ICD over CRT alone in patients with LVSD remains uncertain. None of the trials reported differences in the efficacy of CRT or ICD across patient subgroups, nor did our meta-regression detect any subgroup effects; however, subgroup analyses and meta-regression using aggregate trial data are post-hoc analyses and were underpowered to detect such effects. Examination of individual patient trial data is urgently needed to define which clinical subgroups are most likely to benefit from these devices.
منابع مشابه
On the underutilization of cardiac resynchronization therapy.
Cardiac resynchronization therapy (CRT) is an exciting therapy that can treat patients with systolic heart failure and left ventricular dysfunction who have a wide QRS complex. Indications for its use have been refined and expanded based on recent clinical data and guidelines, yet the rate of new CRT implants in the United States has not changed much over the past 8 years. Many patients receivi...
متن کاملImpact of implantable defibrillators and resynchronization therapy on outcome in patients with left ventricular dysfunction--a meta-analysis.
BACKGROUND The clinical benefits of cardiac resynchronization therapy (CRT) and primary prophylactic implantable cardioverter defibrillator (ICD) in patients with left ventricular systolic dysfunction (LVSD) are debated. OBJECTIVE To evaluate by a meta-analysis the effect of CRT and prophylactic ICD therapy in patients with LVSD. METHODS Eligible trials evaluating the effect of CRT vs. no-C...
متن کاملCardiac resynchronization pacing without defibrillator capability: is this a viable option?
Improved cardiac resynchronization by pacemakers (CRT-P) and implantable defibrillators (CRT-D) benefits cardiac function, reduces heart failure (HF) admissions, and diminishes mortality in patients with severe left ventricular (LV) dysfunction. In terms of mortality benefit, current evidence suggests that CRT-D may be better than CRT-P alone when a broad range of HF patients is considered. How...
متن کاملHyperglycemia-Induced T-Wave Oversensing as a Cause of Cardiac Resynchronization Therapy (CRT) Failure
T-wave oversensing occurs when the counter starts giving dual beeps for every cardiac cycle instead of one. This usually happens when the monitoring lead displays a tall T wave, which is also sharp. R wave sensing algorithms of the devices do not sense T wave because the slow rate of the T wave is much less than that of the R wave. But the slow rate of T waves may change with time and also beca...
متن کاملCardiac resynchronization therapy for mild heart failure: the time has come.
Current guidelines recommend cardiac resynchronization therapy (CRT), previously known as biventricular pacing, in patients with left ventricular (LV) systolic dysfunction (ejection fraction [EF] 35%), QRS prolongation ( 120 ms), and New York Heart Association (NYHA) class III or IV heart failure (HF).1 These recommendations come after multiple prospective, randomized trials demonstrated the be...
متن کاملCardiac resynchronization therapy in asymptomatic or mildly symptomatic heart failure patients in relation to etiology: results from the REVERSE (REsynchronization reVErses Remodeling in Systolic Left vEntricular Dysfunction) study.
OBJECTIVES The purpose of this study was to determine the effects of cardiac resynchronization therapy (CRT) with respect to heart failure etiology among patients in the REVERSE (REsynchronization reVErses Remodeling in Systolic Left vEntricular Dysfunction) study. BACKGROUND CRT improves outcomes in New York Heart Association functional class III/IV heart failure with wide QRS with a more pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Evidence report/technology assessment
دوره 152 شماره
صفحات -
تاریخ انتشار 2007