Type-D personality but not implantable cardioverter-defibrillator indication is associated with impaired health-related quality of life 3 months post-implantation.

نویسندگان

  • Susanne S Pedersen
  • Dominic A M J Theuns
  • Agnes Muskens-Heemskerk
  • Ruud A M Erdman
  • Luc Jordaens
چکیده

AIMS Little is known about the impact of ICD indication (primary vs. secondary) on health-related quality of life (HRQL). Indication may also interact with psychological factors, such as personality. Using a prospective design, we examined whether ICD indication and type-D personality (i.e. experiencing increased negative emotions paired with emotional non-expression) serve as modulators of HRQL at baseline and 3 months post-implantation. METHODS AND RESULTS Consecutively implanted ICD patients (n = 154) completed the Type-D Scale (DS14) at baseline and the Short-Form Health Survey 36 (SF-36) at baseline and 3 months. Of all patients, 82 (53%) received an ICD due to prophylactic reasons; the prevalence of type-D was 23%. Indication had no influence on HRQL (P = 0.75). Further stratification by personality showed a main effect for type-D personality (P < 0.001), with type-D patients generally experiencing poorer HRQL; there was no main effect for indication (P = 0.45) nor was the interaction effect indication by type-D significant (P = 0.22). There was a significant improvement in HRQL over time (P = 0.001). Type-D remained an independent predictor of impaired HRQL, adjusting for clinical factors and shocks during follow-up (P < 0.001). However, in adjusted analysis there was no longer a significant change in HRQL over time (P = 0.099). CONCLUSION Type-D personality but not ICD indication was associated with impaired HRQL at the time of implantation and at 3 months. In the quest for enhancing risk stratification in clinical practice, personality factors, such as type-D, should not be ignored, as both type-D and poor HRQL have been associated with increased risk of mortality in cardiac patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Shock and patient preimplantation type D personality are associated with poor health status in patients with implantable cardioverter-defibrillator.

BACKGROUND Implantable cardioverter-defibrillator (ICD) shock is a critical event to patients associated with well-being after implantation, although other factors may play an equally important role. We compared the association of shock and the patient's preimplantation personality with health status, using a prospective study design. METHODS AND RESULTS Consecutively implanted ICD patients (...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Pre-implantation psychological functioning preserved in majority of implantable cardioverter defibrillator patients 12 months post implantation.

BACKGROUND The impact of ICD therapy on patient well being has typically focused on mean differences between groups, thereby neglecting changes within individuals. Using an intra-individual approach, we examined (i) the prevalence of implantable cardioverter defibrillator (ICD) patients maintaining their pre implantation level of psychological functioning at 12 months, and (ii) factors associat...

متن کامل

Posttraumatic stress 18 months following cardioverter defibrillator implantation: shocks, anxiety, and personality.

OBJECTIVE Posttraumatic stress disorder (PTSD) has been observed in cardiac patients, but little is known about PTSD in implantable cardioverter defibrillator (ICD) patients. We examined the prevalence and predictors (clinical variables, personality, and anxiety) of PTSD in ICD patients. METHOD Three hundred ninety-five ICD patients (20.1% female; mean age = 62.8 ± 10.3 years) from two Dutch ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 9 8  شماره 

صفحات  -

تاریخ انتشار 2007