Development of site-specific locking plates for acetabular fractures.

نویسندگان

  • Meng Xu
  • Li-Hai Zhang
  • Ying-Ze Zhang
  • Chun-Qing He
  • Li-Cheng Zhang
  • Yan Wang
  • Pei-Fu Tang
چکیده

Site-specific locking plates have gained popularity for the treatment of fractures. However, the clinical use of a site-specific locking plate for acetabular fractures remains untested due to production limits. To design a universal site-specific locking plate for acetabular fractures, the 3-dimensional (3D) photographic records of 171 pelvises were retrospectively studied to generate a universal posterior innominate bone surface. Using 3D photographical processing software, the 3D coordinate system was reset according to bony landmarks and was scaled based on the acetabular diameter to allow a direct comparison between surfaces. The measured surface was separated into measurement units. At each measurement unit, the authors calculated the average z-axis values in all samples and obtained the 3D coordinate values of the point cloud that could be reconstructed into the universal surface. A plate was subsequently designed in 3D photographical processing software, and the orientation and distribution of locking screws was included. To manufacture a plate, the data were entered into Unigraphics NX version 6.0 software (Siemens PLM Software, Co, Ltd, Plano, Texas) and a CNC digital milling machine (FANUC Co, Ltd, Yamanashi, Japan). The resulting locking plate fit excellently with the reduced bone surface intraoperatively. Plate contouring was avoided intraoperatively. Universal 3.5-mm locking screws locked successfully into the plate, and their orientations were consistent with the design. No screw yielded to acetabular penetration. This method of designing a site-specific acetabular locking plate is practical, and the plates are suitable for clinical use. These site-specific locking plates may be an option for the treatment of acetabular fractures, particularly in elderly patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Custom-made locked plating for acetabular fracture: a pilot study in 24 consecutive cases.

Clinical implementation of site-specific locking plates for acetabular fracture remains untested. Custom-made locking plates were manufactured using computer-aided design and computer-aided manufacture techniques for acetabular fractures to test this procedure. The 3-dimensional images constructed from computed tomography data of pelvises in patients with acetabular fractures were used for preo...

متن کامل

A biomechanical study of conventional acetabular internal fracture fixation versus locking plate fixation.

BACKGROUND Conventional internal fixation entails the use of an interfragmentary lag screw along with a plate. Not all acetabular fractures are amenable to the placement of an interfragmentary lag screw, and the fracture may be displaced during tightening of the interfragmentary lag screw. Locking plates are a possible solution. We sought to determine whether a locking plate construct can provi...

متن کامل

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Functional Results of Unstable (Type 2) Distal Clavicle Fractures Treated with Superior Anterior Locking Plate

Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 2013