THE STANDARDS OF PRACTICE COMMITTEE (SPC) IS CHARGED BY THE AMERICAN ACADEMY OF SLEEP MEDICINE (AASM) TO PRODUCE TOPICAL reviews and clinical guidelines and practice parameters for the use of clini-
نویسنده
چکیده
We conducted an evidence-based review of literature regarding use of oral appliances (OAs) in the treatment of snoring and obstructive sleep apnea syndrome (OSA) from 1995 until the present. Our structured search revealed 141 articles for systematic scrutiny, of which 87 were suitable for inclusion in the evidence base, including 15 Level I to II randomized controlled trials and 5 of these trials with placebo-controlled treatment. The efficacy of OAs was established for controlling OSA in some but not all patients with success (defined as no more than 10 apneas or hypopneas per hour of sleep) achieved in an average of 52% of treated patients. Effects on sleepiness and quality of life were also demonstrated, but improvements in other neurocognitive outcomes were not consistent. The mechanism of OA therapy is related to opening of the upper airway as demonstrated by imaging and physiologic monitoring. Treatment adherence is variable with patients reporting using the appliance a median of 77% of nights at 1 year. Minor adverse effects were frequent whereas major adverse effects were uncommon. Minor tooth movement and small changes in the occlusion developed in some patients after prolonged use, but the long-term dental significance of this is uncertain. In comparison to continuous positive airway pressure (CPAP), OAs are less efficacious in reducing the apnea hypopnea index (AHI), but OAs appear to be used more (at least by self report), and in many studies were preferred over CPAP when the treatments were compared. OAs have also been compared favorably to surgical modification of the upper airway (uvulopalatopharyngoplasty, UPPP). Comparisons between OAs of different designs have produced variable findings. The literature of OA therapy for OSA now provides better evidence for the efficacy of this treatment modality and considerable guidance regarding the frequency of adverse effects and the indications for use in comparison to CPAP and UPPP. Citation: Ferguson KA; Cartwright R; Rogers R et al. Oral Appliances for Snoring and Obstructive Sleep Apnea: A Review. SLEEP 2006;29(2): 244-262. Disclosure Statement This was not an industry supported study. Dr. Schmidt-Nowara has received research support from Cephalon. Dr. Rogers is a consultant for Respironics, Inc. Dr. Ferguson has received research support from Orphan Medical; is on the board of directors of Critical Outcome Technologies, Inc.; and has participated in speaking engagements supported by Ontario Medical Association, Vitalaire, and GlaxoSmithKline. Dr. Cartwright has indicated no financial conflict of interest. Address correspondence to: Kathleen A. Ferguson, BSc, MD, FRCPC. Associate Professor of Medicine, Division of Respirology, University of Western Ontario, London Health Sciences Centre, 375 South Street, London, Ontario, Canada N6A 4G5. Tel: (519) 667-6586; Fax (519) 667-6584; Email: [email protected]
منابع مشابه
Snoring and Obstructive Sleep Apnea (osa) Are Caused in Part by Repetitive Dynamic Obstruc- Tion of the Oropharyngeal
SNORING AND OBSTRUCTIVE SLEEP APNEA (OSA) ARE CAUSED IN PART BY REPETITIVE DYNAMIC OBSTRUCTION OF THE OROPHARYNGEAL AIRWAY. There is growing epidemiological and experimental evidence that OSA, and to a lesser degree snoring, are associated with a wide variety of adverse health outcomes.1, 2 OSA is considered one of several potentially treatable contributors to systemic hypertension, and has bee...
متن کاملExcessive Daytime Sleepiness Has a Significant Detrimental Impact on Psychological, Social and Vocational Function and Personal Safety,
EXCESSIVE DAYTIME SLEEPINESS HAS A SIGNIFICANT DETRIMENTAL IMPACT ON PSYCHOLOGICAL, SOCIAL AND VOCATIONAL FUNCTION AND PERSONAL SAFETY, thus adversely affecting quality of life. Sleepiness is an important public health issue among individuals who work in fields where the lack of attention can result in injury to self or others such as transportation and healthcare. Hypersomnia of central origin...
متن کاملReview: Non-respiratory Indications for Psg in Children
1451 Polysomnography and Related Procedures in Children—Kotagal et al 1.0 INTRODUCTION In the last three decades, the knowledge and practice of pediatric sleep medicine has grown dramatically, as reflected in the exponential growth of peer reviewed publications regarding pediatric polysomnography (PSG). Comprehensive, attended, in-laboratory (level I) PSG is most often conducted to evaluate and...
متن کاملClinical guideline of neurosurgical practice during the COVID-19 pandemic
Background: Neurosurgery practice conflicts with many challenges during the COVID-19 pandemic; Including the lack of beds in intensive care units, as well as the use of some methods such as drills and trans-nasal and trans-oral approaches that produce aerosols or are directly in contact with patient discharge. Due to these challenges, developing a clinical guideline to help neurosurgeons and me...
متن کاملPhilosophical Contemplation on Evidence-Based Medicine
Background and Objectives: Today, the main basis of diagnosis and treatment in medicine is the obtained evidence from the research. One of the movements that have attempted to establish this basis is evidence-based medicine (EBM). The present review dealt with the philosophical assessment of this subject. Methods: In this study, EBM-related data from books and articles were reviewed. Resu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005