Rapid Quantification of N-Methyl-2-pyrrolidone in Polymer Matrices by Thermal Desorption-GC/MS.

نویسندگان

  • Young-Min Kim
  • Jae Woo Kim
  • Hye Mi Moon
  • Min-Jin Lee
  • Akihiko Hosaka
  • Atsushi Watanabe
  • Norio Teramae
  • Young-Kwon Park
  • Seung-Woon Myung
چکیده

Analysis of a residual solvent in polymeric materials has become an important issue due to the increased regulations and standards for its use. N-Methyl-2-pyrrolidone (NMP) is a solvent widely used in many industries and restricted as one of the chemicals under EU REACH regulations due to its potential harmful effects. In this study, thermal desorption-gas chromatography/mass spectrometry (TD-GC/MS) is applied for the quantitative analysis of NMP with the use of a polymer-coated sample cup. By using the polymer-coated sample cup, the vaporization of NMP was prevented during waiting time before TD-GC/MS analysis. The calibration curve for the TD method showed good linearity (correlation coefficient, r2 = 0.9998) and precision values (below 5.3% RSD). NMP recovery rates in different polymer matrices (PS, PMMA and PVC) were in the range of 98.8 to 106.6% with RSD values below 5.0%. The quantification result (600 mg NMP/kg PVC) for the blind NMP carrying sample in a PVC matrix by TD-GC/MS was higher than that (532 mg NMP/kg PVC) by solvent extraction-GC/MS method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative study of thermal desorption and solvent extraction-gas chromatography-mass spectrometric analysis for the quantification of phthalates in polymers.

For the quantitative analysis of phthalates in polymers, a thermal desorption (TD)-GC-MS method was compared with solvent extraction (SE)-GC-MS methods which require the long pretreatment procedures using large amount of harmful organic solvents. Calibration curves of TD-GC-MS showed good linearity (r(2)>0.9997) and low method detection limit (<30mg/kg with 9.0% RSD). Quantification results for...

متن کامل

Rapid determination of decabromodiphenyl ether in polystyrene by thermal desorption-GC/MS.

A rapid determination of decabromodiphenyl ether (DeBDE) in polystyrene (PS) by thermal desorption (TD)-GC/MS was studied. The TD-GC/MS method using a pyrolysis-GC/MS system allowed the quick quantification of DeBDE in a waste TV back plate composing of a PS flame-retarded with polybrominated diphenyl ethers on the basis of the resulting chromatogram with a ca. 4% relative standard deviation wi...

متن کامل

Determination of residual solvents in pharmaceuticals by thermal desorption-GC/MS.

A novel method for the determination of residual solvents in pharmaceuticals by thermal desorption (TD)-GC/MS has been established. A programmed temperature pyrolyzer (double shot pyrolyzer) is applied for the TD. This method does not require any sample pretreatment and allows very small amounts of the sample. Directly desorbed solvents from intact pharmaceuticals (ca. 1 mg) in the desorption c...

متن کامل

Simultaneous Screening of Major Flame Retardants and Plasticizers in Polymer Materials Using Pyrolyzer/Thermal Desorption Gas Chromatography Mass Spectrometry (Py/TD-GC-MS).

This study was conducted with the aim of achieving the simultaneous screening of various additives in polymer materials by utilizing a solvent-free pyrolyzer/thermal desorption gas chromatography mass spectrometry (Py/TD-GC-MS) method. As a first step to achieve this goal, simultaneous screening has been examined by selecting major substances representing plasticizers and flame retardants, such...

متن کامل

Use of a Deuterated Internal Standard with Pyrolysis-GC/MS Dimeric Marker Analysis to Quantify Tire Tread Particles in the Environment

Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 33 7  شماره 

صفحات  -

تاریخ انتشار 2017