Scatterer size estimation in pulse-echo ultrasound using focused sources: theoretical approximations and simulation analysis.

نویسندگان

  • Timothy A Bigelow
  • William D O'Brien
چکیده

The speckle in ultrasound images has long been thought to contain information related to the tissue microstructure. Many different investigators have analyzed the frequency characteristics of the backscattered signals to estimate the scatterer acoustic concentration and size. Previous work has been mostly restricted to unfocused or weakly focused ultrasound sources, thus limiting its implementation with diagnostically relevant fields. Herein, we derive equations capable of estimating the size of a scatterer for any reasonably focused source provided that the velocity potential field in the focal region can be approximated as a three-dimensional Gaussian beam, scatterers are a sufficient distance from the source, and the field is approximately constant across the scatterer. The calculations show that, when estimating the scatterer size, correcting for focusing requires a generalized attenuation-compensation function that includes both attenuation and focusing along the beam axis. The Gaussian approximation is validated by comparing the ideal velocity potential field for three spherically focused sources with f-numbers of 1, 2, and 4 to the Gaussian approximation for frequencies from 2 to 14 MHz. The theoretical derivations are evaluated by simulating the backscatter by using spherically focused sources (f-numbers of 1, 2, and 4) adjacent to attenuating media (0.05 to 1 dB/cm/MHz) that contain scatterers with Gaussian impedance distributions. The generalized attenuation-compensation function yielded results accurate to 7.2% while the traditional attenuation-compensation functions that neglected focusing had errors as high as 103%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scatterer size estimation in pulse-echo ultrasound using focused sources: calibration measurements and phantom experiments.

In a companion paper [T. A. Bigelow and W. D. O'Brien Jr., J. Acoust. Soc. Am. 116, 578 (2004)], theory, supported by simulations, showed that accurate scatterer size estimates could be obtained using highly focused sources provided that the derived generalized attenuation-compensation function was used and the velocity potential field near the focus could be approximated as a three-dimensional...

متن کامل

Spatial Angular Compounding Technique for H-Scan Ultrasound Imaging.

H-Scan is a new ultrasound imaging technique that relies on matching a model of pulse-echo formation to the mathematics of a class of Gaussian-weighted Hermite polynomials. This technique may be beneficial in the measurement of relative scatterer sizes and in cancer therapy, particularly for early response to drug treatment. Because current H-scan techniques use focused ultrasound data acquisit...

متن کامل

Impact of local attenuation approximations when estimating correlation length from backscattered ultrasound echoes.

Estimating the characteristic correlation length of tissue microstructure from the backscattered power spectrum could improve the diagnostic capability of medical ultrasound. Previously, size estimates were obtained after compensating for source focusing, the frequency-dependent attenuation along the propagation path (total attenuation), and the frequency-dependent attenuation in the scattering...

متن کامل

Comparison of Robust Methods for Shear Wave Speed Estimation by Simulation

Mechanical properties of tissue are often related to the pathological state of tissue. Therefore, non-invasively measuring tissue stiffness has important clinical applications. With the assumption of isotropy, incompressibility and linearity, the shear modulus of tissue is related to its shear wave propagation speed. Acoustic radiation force from a focused ultrasound beam can be used to generat...

متن کامل

Error bounds on ultrasonic scatterer size estimates.

Precision errors that occur in estimating the average scatterer size from pulse-echo ultrasound waveforms are examined in detail. The method-independent lower bound on estimation error is found from the Cramér-Rao inequality for comparison with the predicted error for the measurement technique currently used to estimate scatterer sizes in soft biological tissues. The probability density functio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 116 1  شماره 

صفحات  -

تاریخ انتشار 2004