Restoration of elbow extension via functional electrical stimulation in individuals with tetraplegia.

نویسندگان

  • William D Memberg
  • Patrick E Crago
  • Michael W Keith
چکیده

Functional electrical stimulation of the triceps is a method of restoring elbow extension to individuals with paralyzed triceps. Eleven arms of individuals with cervical-level spinal cord injuries (SCIs) received a triceps electrode as an addition to a hand-grasp neuroprosthesis. Stimulation was controlled either as part of a preprogrammed pattern or via a switch or an accelerometer that was connected to the neuroprosthesis external controller. The outcome measures were (1) elbow extension moments at different elbow positions, (2) performance in controllable workspace experiments, and (3) comparison to an alternative method of providing elbow extension in these individuals--a posterior deltoid (PD) to triceps tendon transfer. Stimulated elbow extension moments in 11 arms ranged from 0.8 to 13.3 N.m. The stimulated elbow extension moments varied with elbow angle in a manner consistent with the length-tension properties of the triceps. Triceps stimulation provided a significantly stronger elbow extension moment than the PD to triceps tendon transfer. The elbow extension moment generated by the tendon transfer and triceps electrode being activated together was always greater than either method used separately. Stimulation of the long head of the triceps should be avoided in persons with weak shoulder abduction, since the long head adducts the shoulder and limits shoulder function in these cases. Statistically, elbow extension neuroprostheses significantly increased the ability to successfully reach and move an object and significantly decreased the time required to acquire an object while reaching.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Natural Control of Triceps Stimulation Using FES

Individuals with C5/C6 spinal cord injury have paralyzed elbow extensors, yet retain weak to strong voluntary control of elbow flexion and shoulder function. Previous studies have shown that functional electrical stimulation (FES) of the triceps provides sufficient elbow extension strength and control to greatly improve function. With triceps stimulation applied at a constant level, elbow angle...

متن کامل

An elbow extension neuroprosthesis for individuals with tetraplegia.

Functional electrical stimulation (FES) of the triceps to restore control of elbow extension was integrated into a portable hand grasp neuroprosthesis for use by people with cervical level spinal cord injury. An accelerometer mounted on the upper arm activated triceps stimulation when the arm was raised above a predetermined threshold angle. Elbow posture was controlled by the subjects voluntar...

متن کامل

Clinical experience of functional electrical stimulation for restoration of tetraplegic hand function

There are some Functional Electrical Stimulation (FES) systems that restore upper limb functions in tetraplegia. Surface electrodes [1], percutaneous intramuscular electrodes [2] and totally implantable electrodes [3] are used for stimulation in these neuroprostheses. The FESMATE system, developed by the Sendai FES Projects in Japan, is a portable multi-channel FES system with percutaneous elec...

متن کامل

Genetic Feedforward-Feedback Controller for Functional Electrical Stimulation Control of Elbow Joint Angle

Background: Functional electrical stimulation (FES) is the most commonly used system for restoring functions after spinal cord injury (SCI). Objective: In this study we investigated feedback PID and feedforward-feedback P-PID controllers for regulating the elbow joint angle. Methods: The controllers were tuned based on a nonlinear muculoskeletal model containing two links, one joint with one de...

متن کامل

A transducer to measure isometric elbow moments.

OBJECTIVE The purpose of this study was to design and implement a transducer to measure accurately the isometric elbow moments produced by individuals with tetraplegia. DESIGN The device needed to be insensitive to off-axis moments and proximal joint motions and be capable of being used over a wide range of elbow and shoulder positions in an outpatient clinic setting. BACKGROUND Measurement...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 40 6  شماره 

صفحات  -

تاریخ انتشار 2003