Turbidimetric determination of prothrombin time by clotting in a centrifugal analyzer.

نویسندگان

  • G O Gogstad
  • K H Dahl
  • A Christophersen
  • A Bjerke
چکیده

Two thromboplastin reagents ("Thrombotest" and "Normotest Automated") were used in evaluation of an automated method for determination of prothrombin time based on turbidimetric measurement of clot formation in a centrifugal analyzer. We used 60 plasma samples from patients with various diseases or being treated with oral anticoagulant and 16 normal plasma samples. Prothrombin times were calculated by a computer connected to the analyzer, a reading being made at either a certain per cent increase in total absorbance or a fixed absorbance increase. Both correlated well with the manual method (r = 0.98-0.99). The reading points best fitting the manually obtained data were estimated by minimizing the residual sum of squares in regression analyses performed at various absorbance increases. The per cent reading was better in this respect. Normotest Automated could be nearly perfectly related to the manual method, whereas Thrombotest showed a (negligibly) small deviation. Reproducibility was good within run (CV less than or equal to 3.2%) as well as between batch of the reagents, as assessed from variation in INR (CV less than or equal to 4.9%). We conclude that turbidimetry of clot formation may be validly used in automation of the prothrombin-time test. The equipment needed and the total time per analysis are about as for chromogenic substrate methods, but reagent cost is considerably lower.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coagulation-time determination with automatic multivariable analysis, by use of a miniature centrifugal fast analyzer.

Use of a miniature Centrifugal Fast Analyzer for the parallel photometric monitoring of the coagulation process is shown to have a number of advantages. These include a choice of optical modes, virtually simultaneous initiation and observation of the coagulation process for a number of patient-plasma samples and an on-board control sample, small sample and reagent volume requirements, and autom...

متن کامل

Clinical evaluation of a fully automated chromogenic method for prothrombin time compared with a conventional coagulation method.

The clinical usefulness of a chromogenic method for prothrombin time (PT) determination has been assessed in a wide range of clinical conditions, and it is compared with the conventional clotting method for PT. The new method appears to be as sensitive as the clotting PT to deficiencies of clotting factors of the extrinsic and common pathway, except for fibrinogen. Patients with proven liver di...

متن کامل

Evaluation of a fully automated centrifugal analyzer for performance of hemostasis tests.

We have evaluated the performance of a centrifugal analyzer, specifically designed for hemostasis tests, for methods based on clotting time as measured by light scattering, or based on splitting of chromogenic substrates. The results were compared with those obtained with a semiautomated coagulometer (clotting tests) or with a manually operated photometer (chromogenic tests). In general, the re...

متن کامل

Automation of the prothrombin time assay on a centrifugal analyser using two different chromogenic substrate reagents.

Methods employing chromogenic substrates for the photometric determination of prothrombin time have several advantages over conventional coagulometric methods. We evaluated the analytical qualities of two recently introduced reagents for the photometric determination of prothrombin time. The assays were performed on a centrifugal analyser. Both reagents showed good precision, even with sample v...

متن کامل

Comparison of turbidimetric and light-scattering measurements of immunoglobulins by use of a centrifugal analyzer with absorbance and fluorescence/light-scattering optics.

We have developed a centrifugal analyzer with both fluorescence/light-scatter and conventional absorbance optics. The instrument is used in this investigation to study the formation of antigen-antibody complexes by light scattering and turbidimetric measurements, and to develop assays for human immunoglobulins G, A, and M. Concentrations are calculated from a nonlinear least-squares fit of cali...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 32 10  شماره 

صفحات  -

تاریخ انتشار 1986