CPR performance in the presence of audiovisual feedback or football shoulder pads

نویسندگان

  • Shota Tanaka
  • Wayne Rodrigues
  • Susan Sotir
  • Ryo Sagisaka
  • Hideharu Tanaka
چکیده

OBJECTIVE The initiation of cardiopulmonary resuscitation (CPR) can be complicated by the use of protective equipment in contact sports, and the rate of success in resuscitating the patient depends on the time from incident to start of CPR. The aim of our study was to see if (1) previous training, (2) the presence of audiovisual feedback and (3) the presence of football shoulder pads (FSP) affected the quality of chest compressions. METHODS Six basic life support certified athletic training students (BLS-ATS), six basic life support certified emergency medical service personnel (BLS-EMS) and six advanced cardiac life support certified emergency medical service personnel (ACLS-EMS) participated in a crossover manikin study. A quasi-experimental repeated measures design was used to measure the chest compression depth (cm), rate (cpm), depth accuracy (%) and rate accuracy (%) on four different conditions by using feedback and/or FSP. Real CPR Help manufactured by ZOLL (Chelmsford, Massachusetts, USA) was used for the audiovisual feedback. Three participants from each group performed 2 min of chest compressions at baseline first, followed by compressions with FSP, with feedback and with both FSP and feedback (FSP+feedback). The other three participants from each group performed compressions at baseline first, followed by compressions with FSP+feedback, feedback and FSP. RESULTS CPR performance did not differ between the groups at baseline (median (IQR), BLS-ATS: 5.0 (4.4-6.1) cm, 114(96-131) cpm; BLS-EMS: 5.4 (4.1-6.4) cm, 112(99-131) cpm; ACLS-EMS: 6.4 (5.7-6.7) cm, 138(113-140) cpm; depth p=0.10, rate p=0.37). A statistically significant difference in the percentage of depth accuracy was found with feedback (median (IQR), 13.8 (0.9-49.2)% vs 69.6 (32.3-85.8)%; p=0.0002). The rate accuracy was changed from 17.1 (0-80.7)% without feedback to 59.2 (17.3-74.3)% with feedback (p=0.50). The use of feedback was effective for depth accuracy, especially in the BLS-ATS group, regardless of the presence of FSP (median (IQR), 22.0 (7.3-36.2)% vs 71.3 (35.4-86.5)%; p=0.0002). CONCLUSIONS The use of audiovisual feedback positively affects the quality of the depth of CPR. Both feedback and FSP do not alter the rate measurements. Medically trained personnel are able to deliver the desired depth regardless of the presence of FSP even though shallower chest compressions depth can be seen in CPR with FSP. A feedback device must be introduced into the athletic training settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of football shoulder pads on pulmonary function.

Restriction of expansion of the lungs or chest wall impedes inflation of the lungs during inhalation. Functional changes occurring during such restriction include reduced pulmonary and/or chest wall compliance, decreases in pulmonary function, and ultimately a decrease in exercise performance. Such restriction can be seen in several pathologic conditions such as scoliosis or obesity, as well as...

متن کامل

The effect of real-time CPR feedback and post event debriefing on patient and processes focused outcomes: A cohort study: trial protocol

BACKGROUND Cardiac arrest affects 30-35, 000 hospitalised patients in the UK every year. For these patients to be given the best chance of survival, high quality cardiopulmonary resuscitation (CPR) must be delivered, however the quality of CPR in real-life is often suboptimal. CPR feedback devices have been shown to improve CPR quality in the pre-hospital setting and post-event debriefing can i...

متن کامل

Meaning-Focused Audiovisual Feedback and EFL Writing Motivation

  Having in mind the high level of challenge in writing as a foreign language, this research provided Iranian EFL learners with audiovisual feedbacks as an alternative of common written feedback and focused on its’ meaningfulness in order to provide an incentive medium for the participants and increase their moti-vation. One hundred young adult female learners in addition to six English languag...

متن کامل

Effect of Using an Audiovisual CPR Feedback Device on Chest Compression Rate and Depth.

INTRODUCTION The aim of the study is to investigate the effect of using Automated External Defibrillator (AED) audiovisual feedback on the quality of cardiopulmonary resuscitation (CPR) in a manikin training setting. MATERIALS AND METHODS Five cycles of 30 chest compressions were performed on a manikin without CPR prompts. After an interval of at least 5 minutes, the participants performed an...

متن کامل

Effect of caregiver gender, age, and feedback prompts on chest compression rate and depth.

BACKGROUND Quality of chest compressions (CC) is an important determinant of resuscitation outcome for cardiac arrest patients. PURPOSE To characterize the quality of CC performed by hospital personnel, evaluate for predictors of CC performance, and determine the effects of audiovisual feedback on CC performance. METHODS Seven hundred and fifty four individuals participated in a CPR quality...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2017